Para.
Name
FL.14
Fault type of the first time
FL.15
Fault type of the second time
Fault type of the third time
FL.16
(latest)
FL.17
Bus voltage at the last fault
FL.18
Output current at the last fault
FL.19
Freq. at the last fault
Para.
Name
Fn.00
Preset operating time
Fn.01
Total operating time
Fn.02
Reserved
Fn.03
Reserved
Para.
Name
FP.00
User password
FP.01
Write-in protection
Parameter
FP.02
initialization
FP.03
Reserved
FP.04
Reserved
Para.
Name
FU.00
Factory password
Group FL: Protection Parameters
0: not fault
1: overcurrent during acceleration (E001)
2: overcurrent during deceleration (E002)
3: overcurrent during constant-speed running (E003)
4: overvoltage during acceleration (E004)
5: overvoltage during deceleration (E005)
6: overvoltage during constant-speed running ( E006)
7: drive's control power supply overvoltage (E007)
8: Reserved
10: Reserved
12: Reserved
14: motor overload (E014)
15: emergency stop or external device fault (E015)
2
16: E
PROM fault (E016)
17: RS485 communication fault (E017)
18: Reserved
20: System disterbed ( E020)
21: Reserved
23: Reserved
0~999V
0.0~999.9A
0.00Hz~650.0Hz
Group Fn: Operating Time
0~65.535K hours
0~65.535K hours
-
-
FP: Protection of Parameters
0: no password
other number: user's password
0: All parameters are allowed to be changed;
1: No parameters can be changed except the F0.02 and FP.01;
2: No parameters can be changed except FP.01.
0: disabled
1: clear fault record
Clear the contents of FL.14~FL.19.
2: restore to factory defaults (parameters listed before FL.14,
excluding F0.08 and FH.00)
-
-
FU: Factory Password
Range
****
EV1000 Series General Purpose Variable Speed Drive User Manual
Range
9: output phase loss (E009)
11: heatsink overheat (E011)
13: drive overload (E013)
19: current-detection circuit fault (E019)
22: Reserved
24: Auto tuning fault ( E024)
Range
Range
Unit
1
Appendix 1 Parameter Set
Unit
Default Modification
1
1V
0.1A
0.01Hz 0.00Hz
Unit
Default
0.001k hour
0
0.001k hour
0
-
-
-
-
Unit
Default
0
0
1
1
1
0
-
-
-
Default
Factory setting
73
0
*
0V
*