Emerson EV1000-2S0004G User Manual page 67

General purpose variable speed drive ev1000 series
Hide thumbs Also See for EV1000-2S0004G:
Table of Contents

Advertisement

Para.
Name
F5.08 Min. input
F5.09 Feedback of min. input
F5.10 Max. input
F5.11 Feedback of max. input
F5.12 Proportional gain Kp
F5.13 Integral gain Ki
F5.14 Sampling cycle T
F5.15 Error limit
Close-loop regulation
F5.16
characteristic
F5.17 Integral regulation
F5.18 Preset frequency
F5.19 Preset frequency hold time 0.0~3600s
F5.20 MS close-loop setting 1
F5.21 MS close-loop setting 2
F5.22 MS close-loop setting 3
F5.23 MS close-loop setting 4
F5.24 MS close-loop setting 5
F5.25 MS close-loop setting 6
F5.26 MS close-loop setting 7
Para.
Name
F6.00
Traverse function selection
F6.01
Traverse mode
F6.02
Preset traverse frequency
Preset traverse frequency hold
F6.03
time
F6.04
Traverse amplitude
F6.05
Step freq.
F6.06
Traverse cycle
F6.07
Rise time of triangular wave
Note: ① The central frequency of traverse operation is default as present reference frequency. The traverse setting becomes
invalid for close-loop and jog.
F5: Close-loop Control
0.0%~ (F5.10) (pecentage of the min. input to 10V/20mA or F1.03 (max.
pulse freq.) )
0.0~100.0%, (pecentage of the min. input to 10V/20mA)
(F5.08) ~100.0% (pecentage of the max. input to 10V/20mA or F1.03
(max. pulse freq.) )
0.0~100% (pecentage of the max. input to 10V/20mA)
0.000~9.999
0.000~9.999
0.01~50.00s
0.0~20.0% (based on close-loop reference)
0: Positive logic
1: Negative logic
Note: it is the relationship between reference and speed.
0: Stop integral regulation when the frequency reaches the upper or lower
limits
1: Continue the integral regulation when the frequency reaches the upper
or lower limits
0.00~650.0Hz
0.00V~10.00V
0.00V~10.00V
0.00V~10.00V
0.00V~10.00V
0.00V~10.00V
0.00V~10.00V
0.00V~10.00V
Group 6: Traverse Operating Parameter
0: disabled
1: enabled
One's place of F6.01: transfer mode
0: auto (according to F6.03)
1: terminal configuration (manually)
Ten's place of F6.01: amplitude control
0: varied amplitude
1: fixed amplitude
Hundred's place of F6.01: start/stop mode
0: start to the state before stop
1: just restart, no other requirement
Thousand's place of F6.01: save traverse state
upon power failure
0: save
1: not save
0.00Hz~650.0Hz
0.0~3600.0s
0.0~50.0% (based on central freq.)
0.0~50.0% (based on F6.04)
0.1~999.9s
0.0~100.0% (traverse cycle)
EV1000 Series General Purpose Variable Speed Drive User Manual
Range
Range
Appendix 1 Parameter Set
Unit
Default Modification
0.1%
0.0
0.1%
20.0%
0.1%
100.0%
0.1%
100.0%
0.001
0.050
0.001
0.050
0.01s
0.50s
0.1%
2.0%
1
0
1
0
0.01Hz 0.00Hz
0.1s
0.0s
0.01V
0.00V
0.01V
0.00V
0.01V
0.00V
0.01V
0.00V
0.01V
0.00V
0.01V
0.00V
0.01V
0.00V
Unit
Default
Modification
1
0
1
0000
0.01Hz
0.00Hz
0.1s
0.0s
0.1%
0.0%
0.1%
0.0%
0.1s
10.0s
0.1%
50.0%
65
×
×
×
×
×

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents