9. Technical data Solida

Model
Equipment
Weight with cladding (steel panels)
Weight with cladding (ceramic)
Height
Width
Depth
Flue gas pipe connection
Heating output
Efficiency (rated heat capacity)
Efficiency (partial load)
Minimum chimney draught
Flue gas temperatures (min/max)
Flue gas flow rate in g/s (min/max)
CO
content in flue gas (min/max)
2
CO content in flue gas
Chimney design recommended
Fuel tank capacity
Burning duration
Permitted fuels: Low-dust wood pellets,
ÖNORM M 7135, DIN 51731, DIN Plus
Room heating capacity (dependent on building
insulation)
Power supply
Electrical power consumption
Maximum during 7 minute ignition
Heating operation
Room thermostat
Ceramic ignition
Solida
PR 08 02 01
PR 10 03 01
140 kg
150 kg
1045 mm
580 mm
532 mm
ø 100 mm
2.4 - 8.0 kW
2.4 - 10.0 kW
92.4%
93.9%
0 Pa
73°C / 118°C
73°C / 140°C
3.0 / 6.1
3.0 / 7.0
5.8% / 9.5%
5.8% / 10.4%
< 0.03% Vol.
Moisture resistant
30 kg
Up to 60 hours
Up to 50
Ø 6 mm wood pellets, length
10 – 30 mm
Up to 200 m³
Up to 300 m³
230 V / 50 Hz
300 W
25 / 80 W
Fitted
Fitted
Solida
91.4%
93.9%
hours