Technical Data - calimax PWS 0601-A Operating Manual

Table of Contents

Advertisement

10 Technical data

Model
Controller
Heating output
Water output
Height
Width
Depth
Weight
Room heating capacity*
Flue pipe connection
Fresh-air connection
Minimum flue draft at the connection
Recommended flue
Fuel content
Burn duration:**
Efficiency at nominal heating capacity***
Efficiency at partial load***
Flue-gas temperature at connection (min/max)
Flue gas mass flow (min/max)
CO2 content in exhaust gas (min/max)
CO content in the exhaust gas
Power connection
Electrical power input (without UWP)
Electrical ignition
Safety temperature limiter (STL)
Max. operating pressure
Required volume of combustion air
Approved fuel
*
Room-heating capacity varies with the quality of heat insulation and amount of ventilation.
**
Burn duration varies with heat output and quality of fuel.
***
Measured under test conditions.
Product type approved by TÜV Munich to EN 14785.
Conforms with emission limits according to Art. 15a B-V and 1. BImSchV, stage 2.
Regional legislation with respect to flue configuration, fire safety, place of installation, etc. should be
observed at all times.
PWS 0601-A
Max3
2.3 to 6.0 kW
Max 4.6 kW
942 mm (incl. adjustable
feet)
502 mm
545 mm
approx. 125 kg
Up to 210 m³
Ø 100 external
Ø 50 external
0 Pa
damp-proof
20 kg
up to 36 h
96.4 %
97.7 %
58 °C / 96 °C
2.2 g/s / 3.7 g/s
6.9 Vol% / 10.9 Vol%
< 0.01 Vol%
230 V / 50 Hz
30 to 60 W
integrated
included in scope of supply
approx. 30 m³/h
low-dust wood pellets
according to EN 14961-2 (class A1), EN plus (class A1)
( ÖNORM M7135, DIN 51731)
22
PWS 1201-A
Max3
2.3 to 12.0 kW
Max 10.0 kW
1100 mm (incl. adjustable
feet)
617 mm
596 mm
165 kg
420 m³
Ø 100 external
Ø 60 external
0 Pa
damp-proof
32 kg
up to 45 h
94.9 %
97.7 %
53 °C / 112 °C
3.0 g/s / 7.0 g/s
8.2 Vol% / 11.7 Vol%
< 0.02 Vol%
230 V / 50 Hz
30 to 100 W
integrated
3 bar

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Twist 12Pws 1201-aTwist 6

Table of Contents