Minuteman Encompass EC1000RT2U User Manual

Minuteman Encompass EC1000RT2U User Manual

On-line ups series

Advertisement

Encompass RT
On-Line UPS Series
User's Manual
Para Systems, Inc.
1455 Lemay Dr.
Carrollton, TX 75007
Phone: 1-972-446-7363
Fax: 1-972-446-9011
Internet: minutemanups.com
UPS Sizing: sizemyups.com
PN - 34000519 R2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Encompass EC1000RT2U and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Minuteman Encompass EC1000RT2U

  • Page 1 Encompass RT On-Line UPS Series User's Manual Para Systems, Inc. 1455 Lemay Dr. Carrollton, TX 75007 Phone: 1-972-446-7363 Fax: 1-972-446-9011 Internet: minutemanups.com UPS Sizing: sizemyups.com PN - 34000519 R2...
  • Page 2: Table Of Contents

    Table Of Contents Introduction Controls and Indicators Installation Operation Configurable Parameters & Settings Obtaining Service Troubleshooting Replacing the Battery Specifications Limited Product Warranty A1. Declaration of Conformity...
  • Page 3: Introduction

    WARNING: Qualified Service Personnel ONLY must perform the Installa- To ensure reliable operation of the UPS and to protect the UPS from over- tion and Servicing of these UPS systems. MINUTEMAN accepts no liabilities heating, these vents and openings must not be blocked or covered. Do not and is not limited to: injury to the Service Personnel, or damages to;...
  • Page 4 CAUTION! Receiving Inspection To de-energize the outputs of the UPS: After removing your UPS from its carton, it should be inspected for damage 1. If the UPS is on press and then release the OFF button after the audible that may have occurred in shipping. Immediately notify the carrier and place alarm beeps twice to turn the UPS off.
  • Page 5: Controls And Indicators

    Chapter 2: Controls and Indicators 1. Displays the power flow of the UPS: AC Mode Power Flow Bypass Mode Power Flow Battery Mode Power Flow 1. The ON button is to turn the UPS on. Pressing the ON button during the 2.
  • Page 6: Installation

    REAR PANEL Input Power Plug Model # Output Power Receptacles (All power cords are 10ft) NEMA 5-15P EC1000RT2U 6-NEMA 5-15R (Controllable) EC1500RT2U NEMA 5-15P 6-NEMA 5-15R (Controllable) EC2000RT2U NEMA 5-20P 6-NEMA 5-15/20R (Controllable) 6-NEMA 5-15/20R (Controllable) EC3000RT2U NEMA L5-30P 1-NEMA L5-30R (Always On) Chapter 3: Installation INSTALLATION PLACEMENT This UPS series is ONLY intended to be installed in an indoor temperature con-...
  • Page 7 RACKMOUNT CONFIGURATION CONNECTING THE BATTERIES (QUALIFIED SERVICE PERSONNEL ONLY) This UPS series comes with mounting brackets for the standard 19" (46.5cm) Please read all of the WARNINGS and CAUTIONS before attempting to con- rack pre-installed on the UPS. There are optional Rail Kits for the 4-post nect the batteries.
  • Page 8 TOWER CONFIGURATION CONNECTING YOUR EQUIPMENT The tower configuration allows the user to install the UPS in the up-right posi- Plug the equipment into the output receptacles on the rear panel of the UPS. tion. The tower brackets are provided with the UPS. WARNING: Use two or Ensure that you do not exceed the maximum output rating of the UPS (refer to more people when installing the UPS, the UPS is extremely heavy.
  • Page 9: Operation

    The UPS will charge the batteries when the UPS is in the on or off position as COMMUNICATIONS PORT CONNECTION (OPTIONAL) long as the UPS is plugged into the wall outlet and there is an acceptable AC The Power Monitoring Software and interface cables can be used with the voltage present (55V (load dependent) - 150VAC).
  • Page 10 Software Download Center. Please download (Free of Charge) the latest (Always On) does not support the "Load Shedding Function". version of the Minuteman SentryHD software. See the software CD for the ECONOMY MODE (ECO) FUNCTION installation of the Power Monitoring Software.
  • Page 11 ALARMS Chapter 5: Configurable Parameters and Settings ON BATTERY When the UPS is operating on the batteries, the On-Battery icon will illumi- (These items may require optional software or hardware) nate, the Utility power LED (Green) will extinguish and the audible alarm will sound one beep every ten-seconds.
  • Page 12: Obtaining Service

    Para Systems Inc. Er38: Failed to synchronize Turn the UPS off, unplug the power cord, wait for 5-minutes and MINUTEMAN UPS with utility input. then restart the UPS. If the error did not clear call for service. 1809 W. Frankford Road, Suite 150 Carrollton, TX 75007 Er39: Low Battery Capacity.
  • Page 13: Replacing The Battery

    Chapter 8: Replacing the Battery BATTERY REPLACEMENT PROCEDURE PLEASE READ THE CAUTIONS AND WARNINGS BEFORE ATTEMPTING QUALIFIED SERVICE PERSONNEL ONLY TO REPLACE THE BATTERY MODULE Hot-swappable batteries mean that the battery modules can be replaced with- Please read all of the WARNINGS and CAUTIONS before attempting to ser- out powering down the whole UPS system.
  • Page 14: Specifications

    10.Grasp the battery pull tab and gently pull the battery module out of the UPS Chapter 9: Specifications and set it aside. (FIG. 3) NOTE: Use Caution, the battery module is heavy. SYSTEM SPECIFICATIONS 11. Slide the new battery module into the UPS. 12.Re-install the battery retaining bracket.
  • Page 15: Limited Product Warranty

    Chapter 10: Limited Product Warranty BATTERY SYSTEM Battery Type Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid Para Systems, Inc. (Para Systems) warrants this equipment, when properly applied and Typical Recharge Time 8-hours to 90% after full load discharge operated within specified conditions, against faulty materials or workmanship for a pe- Typical Battery Life riod of three years from the date of purchase.
  • Page 16: A1. Declaration Of Conformity

    Standard(s) to which Conformity is declared: EN62040-2, IEC61000-2-2 IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4- 6, IEC61000-4-8, UL1778, CSA 22.2 no. 107.3-14, FCC Class A Manufacturer’s Name: Para Systems, Inc. (MINUTEMAN UPS) Manufacturer’s Address: 1455 LeMay Drive Carrollton, Texas 75007 USA Type of Equipment: Uninterruptible Power Supplies (UPS)

Table of Contents