Enspire Series UPS
EN750LCD / EN900LCD
User's Manual
Para Systems, Inc.
1455 LeMay Dr.
Carrollton, TX 75007
Phone: 1-972-446-7363
Fax: 1-972-446-9011
Internet: minutemanups.com
UPS Sizing: sizemyups.com
PN - 34000496 R2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EN750LCD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Minuteman EN750LCD

  • Page 1 Enspire Series UPS EN750LCD / EN900LCD User's Manual Para Systems, Inc. 1455 LeMay Dr. Carrollton, TX 75007 Phone: 1-972-446-7363 Fax: 1-972-446-9011 Internet: minutemanups.com UPS Sizing: sizemyups.com PN - 34000496 R2...
  • Page 2: Table Of Contents

    Table Of Contents Introduction Controls and Indicators Installation Operation Obtaining Service Troubleshooting Replacing the Battery Specifications Limited Product Warranty A1. Declaration of Conformity...
  • Page 3: Introduction

    Please read ATTENTION! Cette série d'onduleurs est uniquement destinée à être installée this manual before installing your Enspire Series UPS, models EN750LCD, dans un environnement intérieur à température contrôlée, exempt de contaminants EN900LCD as it provides important information that should be followed during conducteurs.
  • Page 4 WARNING: Qualified Service Personnel ONLY must perform the Installa- self-test the UPS will be ready for normal operation. To turn tion and Servicing of these UPS systems. MINUTEMAN accepts no liabilities the UPS off: press and hold the On/Off button until the alarm and is not limited to: injury to the Service Personnel, or damages to;...
  • Page 5: Controls And Indicators

    Model # Input Power Cord Output Power Receptacles ranty, guarantee, or undertaking, either expressly or implicitly, including but EN750LCD 5 - NEMA 5-15R Battery Backup & Surge not limited to the completeness, faultlessness, accuracy, non-infringement, NEMA 5-15P W/6 ft cord...
  • Page 6: Installation

    The AC normal icon will be on when the UPS is operating in the Chapter 3: Installation normal AC mode and will turn off when the UPS is operating in the Battery mode. INSTALLATION PLACEMENT The On-Battery icon will turn on when the UPS is operating in the Battery mode and will turn off when the UPS is operating in the AC normal mode.
  • Page 7 Please go to our web site at www.minutemanups.com/support, then printer, copier, vacuum cleaner or any other large electrical device into the output of look under Downloads, and then Software Download Center. Please download the UPS. (Free of Charge) the latest version of the Minuteman SentryHD software.
  • Page 8: Operation

    USB COMMUNICATIONS PORT CONNECTION (OPTIONAL) TURNING THE UPS ON / OFF The EN750LCD and EN900LCD support USB communications. The power moni- To turn the UPS on: press and hold the On/Off button until the alarm sounds one beep and then release. Then in aproximately twenty seconds the UPS will perform a five toring software and interface cable can be used with the UPS.
  • Page 9: Obtaining Service

    RMA # marked on the outside of the package. Beeping 6. Return the unit by insured, prepaid carrier to: The unit is off, plugged into Para Systems Inc. MINUTEMAN UPS the wall outlet 1809 W. Frankford Road, Suite 150 and charging Carrollton, TX 75007 the battery...
  • Page 10: Troubleshooting

    Chapter 6: Troubleshooting Chapter 7: Replacing the Battery REPLACING THE BATTERY Symptom / Error Code Cause / What To Do (QUALIFIED SERVICE PERSONNEL ONLY) Press the On/Off button and release after one beep. UPS will not turn on. Please read all of the WARNINGS and CAUTIONS before attempting to ser- Reset the input circuit breaker by pressing the UPS operates in battery vice the batteries.
  • Page 11 9. Disconnect the battery positive (Red) wire and set the old battery module ne requièrent aucun entretien. aside. (FIG. 2) Do not short the battery positive wire to the battery negative wire. EN750LCD EN900LCD Model # Verify proper polarity. Connect the battery positive (Red) wire to the battery po-...
  • Page 12: Specifications

    FIG. 2 Chapter 8: Specifications SYSTEM SPECIFICATIONS Model Number EN900LCD EN750LCD Topology Standby, Simulated Sine Wave 900VA 750VA Maximum Power Capacity 450W 500W INPUT Number of Phase Single (1∅ 2W +G) Nominal Voltage 120VAC Acceptable Input voltage 0 - 150VAC...
  • Page 13: Limited Product Warranty

    Chapter 9: Limited Product Warranty BATTERY SYSTEM Battery Type Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid Para Systems, Inc. (Para Systems) warrants this equipment, when properly applied and Typical Recharge Time 8-hours to 90% capacity from a full load discharge operated within specified conditions, against faulty materials (excluding the batteries) or Typical Battery Life 3 to 5 years.
  • Page 14: A1. Declaration Of Conformity

    EN62040-2, IEC61000-2-2 IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEEE C62.41 Category A1, UL1778, CSA 22.2 no. 107.3-14 / R: 2014, FCC Class B Manufacturer’s Name: Para Systems, Inc. (MINUTEMAN UPS) Manufacturer’s Address: 1455 LeMay Drive Carrollton, Texas 75007 USA Type of Equipment: Uninterruptible Power Supplies (UPS)