Summary of Contents for Minuteman Enterprise Series

  • Page 1 1-866-207-6631 | sales@rackmountsolutions.net www.rackmountsolutions.net...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Enterprise Series Introduction Controls and Indicators Installation Operation Troubleshooting Replacing the Battery Obtaining Service Specifications Configurable Parameters & Settings Limited Product Warranty Declaration of Conformity © Copyright Para Systems, Inc., 2000 Owner's Manual...
  • Page 3: Introduction

    IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS ! Please read the manual before installing your Enterprise Series UPS. It provides the information that should be followed during installation and maintenance of the UPS and the batteries allowing you to correctly set up your system for the maximum safety and performance.
  • Page 4 PLEASE SAVE THE PACKING MATERIALS! WARNING: INSIDE THIS POWER SUPPLY ARE ENERGIZED FROM THE BATTERY EVEN WHEN THE AC INPUT POWER IS DISCONNECTED. TO DE-ENERGIZE THE OUTPUTS OF THE UPS: 1. IF THE UPS IS ON PRESS THE ON/OFF BUTTON FOR 1 SECOND 2.
  • Page 5: Controls And Indicators

    CONTROLS AND INDICATORS RONT ANEL On-Line/On-Battery/Boost/Buck LED Fault LED Overload LED Weak/Bad Battery LED Site Wiring Fault LED Press and release the ON/OFF/TEST button after one beep to turn the unit ON or OFF (see section 4) On-Line The On-Line/On-Battery/Boost and Buck (green) LED illuminates in a steady state when the UPS is on and supplying AC power to the load.
  • Page 6: Installation

    ANEL (120Vac models shown) 1. The computer interface port is for the UPS monitoring and control. (see section 3) 2. The RJ-45/RJ-11 modular connectors are used for 10 Base-T network/single line telephone surge protection. (see section 3) 3. The output receptacles are NEMA 5-15R type. (IEC output sockets on 230Vac models) 4.
  • Page 7 Be sure to read the installation placement and all the cautions before installing the UPS. The Enterprise series UPS has external Battery Pack capability, please observe the following warning when connecting the Battery Pack(s). WARNING! DO NOT PLUG THE BATTERY PACK'S POWER CORD INTO THE UPS's OUTPUT RECEPTACLES, DAMAGE TO THE BATTERY PACK'S INTERNAL CHARGER MAY OCCUR.
  • Page 8 The Tower Configuration allows the user to install the UPS in the up-right position next to the tower computer. There is a tower bracket kit available for the UPS. Use CAUTION, the UPS is extremely heavy. Once the location of the UPS has been determined, lay the UPS down flat on a desk or a table.
  • Page 9 The Rackmount Configuration comes with mounting brackets for the standard 19" (46.5cm) rack. The mounting brackets to fit a 23" (59.2cm) standard rack are also available. The screws for mounting the UPS to the rack are not included (screw size varies with rack size).
  • Page 10: Operation

    HARGING ATTERY The Enterprise Series UPS will charge the internal batteries whenever the unit is connected to an AC source and the circuit breaker on the back panel is in the "On" position. It is recommended that the UPS's batteries be charged for a minimum of 4 hours before use. The UPS may be used immediately, however, the “on battery”...
  • Page 11 The communications port is a standard DB9 female with both RS232 and simulated contact closure capability. The Enterprise series units will poll the port and activate the port for RS232 or contact closure in accordance with the type of cable it finds connected to the port.
  • Page 12: Troubleshooting

    TROUBLESHOOTING Symptom On / Off / Test button not UPS will not turn on pushed Input AC circuit breaker is UPS operates in tripped battery mode only, even though there is normal AC present Fault LED is UPS has detected an internal illuminated fault The Site Wiring Fault...
  • Page 13: Replacing The Battery

    REPLACING THE BATTERY EPLACING ATTERY The Enterprise Series UPS has an easy to replace hot-swappable battery(s). Please read the following warning statements before attempting to service the battery(s). NOTE: If there is a power interruption while replacing the hot-swappable batteries, with the UPS on, the load will not be backed up.
  • Page 14 ATTERY EPLACEMENT ROCEDURE PLEASE READ THE CAUTIONS BEFORE ATTEMPTING TO REPLACE THE BATTERIES Hot-swappable batteries means that the batteries can be replaced without powering down the whole UPS system. NOTE: If there is a power interruption while replacing the hot- swappable batteries, with the UPS on, the load will not be backed up.
  • Page 15: Obtaining Service

    OBTAINING SERVICE UPS R EQUIRES 1.Use the TROUBLESHOOTING section to eliminate obvious causes. 2.Verify there are no circuit breakers tripped. A tripped circuit breaker is the most common problem. 3.Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem call or fax MINUTEMAN Technical Support at the following numbers;...
  • Page 16: Specifications

    SPECIFICATIONS NOTE: 230Vac Specs Shown In ( ) Acceptable input voltage Input voltage (on-line operation) Output voltage Nominal input frequency Input protection Frequency limits (on-line operation) Transfer time Maximum load On-battery output voltage On-battery frequency On-battery waveshape Protection Surge energy rating (one time, 10/1000 us waveform) Surge current capability (one time, 8/20 us waveform)
  • Page 17: Configurable Parameters & Settings

    CONFIGURABLE PARAMETERS AND SETTINGS (These items require optional software or hardware) FUNCTION FACTORY DEFAULT UPS ID Enterprise Series Battery install Date of manufacture date Battery life in 1826 days Enable/ Enabled Disable auto restart Set audible Enabled alarm state Shutdown...
  • Page 18 Customized Output Receptacle Panels The Enterprise series UPS has a removable receptacle panel. The receptacle panel can be configured with one locking receptacle and two duplex receptacles. This will allow the user to customize the output receptacles for their specific applications. MINUTEMAN will only use UL or CE approved receptacles.
  • Page 19: Limited Product Warranty

    LIMITED PRODUCT WARRANTY Para Systems Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship for a period of three years from the date of manufacture. For equipment sites within the United States and Canada, this warranty covers repair or replacement of defective equipment at the discretion of Para Systems.
  • Page 20: Declaration Of Conformity

    DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC, 7/23/EEC Standard(s) to which Conformity is declared: EN50091-2, EN60555-2, EN61000-3, Manufacturer’s Name: Manufacturer’s Address: 1455 LeMay Drive Type of Equipment: Uninterruptible Power Supplies Model No: E500 (Y), E750 (Y), E1100 (Y), E1500 (Y), E2300 (Y), E3200 (Y) Year of Manufacture: Beginning May 4, 2000 I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s).
  • Page 21 Notes:...