Table Of Contents Introduction Controls and Indicators Installation Operation Troubleshooting Replacing the Battery Obtaining Service Specifications Limited Product Warranty A1. Declaration of Conformity...
Standard for the Protection of Electronic Computer/Data Processing Equip- and manufactured to provide many years of trouble free service. Please read ment ANSI/NFPA 75. this manual before installing your Enspire Series UPS, models EN350, EN550 as it provides important information that should be followed during the installa- CAUTION!
Page 4
Immediately notify the carrier and place of EN550 Model EN350 purchase if any damage is found. Warranty claims for damage caused by the Total harmonic carrier will not be honored. The packing materials that your UPS was shipped in are carefully designed to minimize any shipping damage.
10.USB Communications Port (EN550 only): UPS monitoring and control. 11. RJ11/45 Single line Phone/Network protection port. Model # Input Power Cord Output Power Receptacles EN350 4 - NEMA 5-15R Battery Backup & Surge NEMA 5-15P W/4 ft cord EN550 4 - NEMA 5-15R Surge Only...
Chapter 3: Installation 4. Verify proper polarity. Connect the battery positive (Red) wire to the battery positive (Red) terminal. (FIG 3) 5. Reinstall the battery. INSTALLATION PLACEMENT 6. Reinstall the battery door onto the UPS and slide inward. 7. Continue with the rest of the Installation. FIG.
POWER MONITORING SOFTWARE nected equipment and start recharging the batteries. The EN550 supports Minuteman's SentryHD power monitoring software. Please go to our web site at www.minutemanups.com/support, then look under Downloads, Block Diagram of the Basic Wiring and Internal Circuit Configuration and then Software Download Center.
Page 8
TURNING THE UPS ON / OFF ALARMS To turn the UPS on: press and hold the On/Off button until the alarm sounds one beep and then release. Then in aproximately twenty seconds the UPS will BATTERY MODE perform a five second self-test. Once the UPS has passed its self-test the When the UPS is operating in the Battery mode, the AC normal LED will turn UPS will be ready for normal operation.
CAUTION: Replace the batteries with the same number and type as originally installed in the UPS. These batteries have pressure operated vents. These UPSs contain sealed non-spillable maintenance-free lead acid batteries. EN550 EN350 Model # Battery Module BM0067 Part #...
Page 10
BATTERY REPLACEMENT PROCEDURE FIG. 2 (QUALIFIED SERVICE PERSONNEL ONLY) PLEASE READ THE CAUTIONS AND WARNINGS BEFORE ATTEMPTING TO REPLACE THE BATTERY MODULE. Hot-swappable batteries mean that the battery module can be replaced without powering down the whole UPS system. NOTE: If there is a power interruption while replacing the hot-swappable battery module, with the UPS on, the load will not be backed up.
1. Use the Troubleshooting section to eliminate obvious causes. Model Number EN550 EN350 2. Verify there are no tripped circuit breakers and that the batteries are good. A tripped circuit breaker and defective batteries are the most common iss- Topology Standby, Simulated Sine Wave ues.
Chapter 9: Limited Product Warranty BATTERY SYSTEM Battery Type Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid Para Systems, Inc. (Para Systems) warrants this equipment, when properly applied and Typical Recharge Time 8-hours to 90% capacity from a full load discharge operated within specified conditions, against faulty materials (excluding the batteries) or Typical Battery Life 3 to 5 years.