Note: the recommended height of cavity is 2134mm for use with stainless door panels.
IMPORTANT!
Safety requires refrigerators to be stable when door and/or drawer, are open. The anti-tip bracket and fittings supplied must be fitted to the wall of the finished enclosure to withstand
a 100kg load. This will prevent the possibility of the refrigerator tipping forward, when door and/or drawer, are open.
WARNING!
Failure to follow instructions can lead to serious injury or death.
When fastening with masonry plugs and/or screws:
Ensure the screws avoid electrical, gas and water conduits.
Ensure the surface the bracket is fastened to withstands a 100kg load.
Ensure light-weight masonry material such as cinder block and new concrete (no curing time) are not used in installation.
Do not use metallic materials that may corrode, stain and/or damage the enclosure
For 2134mm cavity installation
Wooden/plaster board wall installation
Project the end of the above finished enclosure to the centre of the back wall and
1
subtract 164mm. This will locate the contact surface between the bracket and the
appliance (refer to A).
Ensure a structural beam/wall stud closest to the centre of the wall enclosure is located.
Fix bracket to the wall with screws x4 (#10 x 40 pan head Phillips screws).
2
Ensure screws hold tight and the bracket overlaps the appliance when it is positioned
(min. 60mm) for a secure hold.
Solid wall installation
Project the end of the above finished enclosure to the centre of the back wall and
1
subtract 164mm. This will locate the contact surface between the bracket and the
appliance (refer to B).
Mark screw locations to drill Ø 6mm x 35mm deep holes. Hammer masonry plugs
2
into the wall until flush x4. Fix bracket to the wall with screws x4
(#10 x 40 pan head Phillips screws). Ensure screws hold tight.
Spacer installation
If a minimum 60mm overlap cannot be achieved we recommend fastening a solid
spacer (wooden beam etc) behind the bracket.
Ensure the length of the spacer corresponds to the enclosure's width. Always
1
secure the spacer to existing studs on the enclosure wall (refer to C).
Fix bracket to the spacer with screws x4 (#10 x 40 pan head Phillips screws).
2
Ensure screws hold tight and the bracket overlaps the appliance when it is
positioned (min. 60mm) for a secure hold.
8
2134mm HEIGHT CAVITY – ATTACH ANTI-TIP BRACKET
Subtract 164mm from
above finished enclosure
A
min. 60mm
overlap
PROFILE VIEW
Subtract 164mm from
above finished enclosure
B
min. 60mm
overlap
PROFILE VIEW
Subtract 164mm from
above finished enclosure
C
min. 60mm
overlap
PROFILE VIEW
Bracket
Bracket
Spacer
Bracket
15