Do not use the SurePower Single Bay Charger in environmental conditions that fall outside
of those specified in Chapter 6, "Product Specifications—SurePower Single Bay Charger."
Using the SurePower Single Bay Charger in environmental conditions that fall outside those
described in the product specifications can result in failure of the unit.
Do not use the SurePower Single Bay Charger in the presence of Electrosurical Units
(ESU).
Do not short the power output pins (battery mating pins) of the charger.
To avoid the risk of electric shock, the SurePower Single Bay Charger must only be
connected to a supply mains with protective earth.
Do not use the SurePower Single Bay Charger in the rain.

Cautions

Follow all recommended maintenance instructions. If a problem occurs, obtain service
immediately.
Do not use ketones (MEK, acetone, etc.) to clean the SurePower Single Bay Charger.
Do not sterilize or autoclave the SurePower Single Bay Charger.
Do not touch the exposed pins in the charging bay -- if the pins are damaged, the charging
bay won't be usable. These pins do not pose an electrical hazard.
Do not install batteries into Monitor/Defibrillators or a SurePower Single Bay Charger that
is not plugged into live AC mains when storage may exceed 90 days. Battery damage may
occur.
Do not connect any cables or devices to the covered connector port -- the connector port is
only for ZOLL factory use.
Do not remove or discard the connector port cover.

Notes

If you are disposing of your SurePower Single Bay Charger, contact your local authorities
to determine the requirements for the recycling and disposal of electrical equipment and
follow those requirements.
The end-of-life of the SurePower Single Bay Charger is determined by the availability of
replacement parts and service for the unit. Contact ZOLL's Technical Service Department
for information on the availability of replacement parts and service for the SurePower
Single Bay Charger.

FDA Tracking Requirements

U.S. Federal Law (21 CFR 821) requires the tracking of defibrillators. Under this law, owners
of this device must notify ZOLL Medical Corporation if this product is
received
lost, stolen, or destroyed
donated, resold, or otherwise distributed to a different organization
If any such event occurs, contact ZOLL Medical Corporation in writing with the following
information:
1. Originator's organization- Company name, address, contact name, and contact phone
number
Part number, model number, and serial number of the device
2.
x
www.zoll.com
9650-000272-05 Rev. B