MEMORY MAP
Table 3: Modbus Memory Map (Sheet 35 of 40)
ADDR
1B74
Underfrequency Restoration Delay
1B75
Underfrequency Restoration Incomplete Sequence Time
TRANSFER (read/write setpoints)
1B80
Transfer Function
1B81
Transfer Delay This Source
1B82
Transfer Delay Other Source
1B83
Block Trip On Double Loss
1B84
Transfer Delay Select to Trip
1B85
Transfer Ready Operate Relay 3
1B86
Bus Transfer Logic Scheme
AUTORECLOSE SETUP (read/write setpoints, 760 only)
1BA0
Autoreclose Function
1BA1
Number of Reclosure Shots
1BA2
Autoreclose Reset Time
1BA3
Autoreclose Block Time Upon Manual Close
1BA4
Incomplete Sequence Time
1BA5
Reclosure Enabled Relays
1BA6
Reclose In Progress Relays
1BA7
Reclosure Lockout Relays
8
Autoreclose External Close Logic
1BA8
AUTORECLOSE RATE SUPERVISION (read/write setpoints, 760 only)
8
Rate Supervision Function
1BAA
8
Max Autoreclose Rate
1BAB
8
Rate Supervision Relays
1BAC
CURRENT SUPERVISION (read/write setpoints, 760 only)
1BB0
Current Supervision Function
2
3 Shots For Current Above
1BB1
2
2 Shots For Current Above
1BB2
2
1 Shot For Current Above
1BB3
1BB4
Current Supervision To Lockout
2
Lockout For Current Above
1BB5
ZONE COORDINATION (read/write setpoints, 760 only)
1
Zone Coordination Function
1BB8
1
Phase Current Increase
1BB9
1
Neutral Current Increase
1BBA
1
Maximum fault Clearing Time
1BBB
RECLOSURE SHOT 1 (read/write setpoints, 760 only)
2
Deadtime Before Reclosure 1
1BC0
1
Select Setpoint Group
1BC1
2
Overcurrent Blocking Flags
1BC2
1
Phase Time Overcurrent 1 Raised Pickup
1BC3
1
Neutral Time Overcurrent 1 Raised Pickup
1BC4
1
Ground Time Overcurrent Raised Pickup
1BC5
1
Negative Sequence Time Overcurrent Raised Pickup
1BC6
3
Sensitive Ground Time Overcurrent Raised Pickup
1BC7
RECLOSURE SHOT 2 (read/write setpoints, 760 only)
2
Deadtime Before Reclosure 2
1BD0
1
Select Setpoint Group
1BD1
2
Overcurrent Blocking Flags
1BD2
1 2 3 4 5 6 7 8 9 10 11 12 13
For explanation of Table footnotes, see the Memory Map Notes at the end of this table.
4 - 40
DESCRIPTION
CHAPTER 4: MODBUS MEMORY MAP
RANGE
UNITS
0 to 10000
s
1 to 10,000
min.
---
---
0.0 to 10.0
s
0.0 to 10.0
s
---
---
0.0 to 10.0
s
---
---
0 to 1
---
---
---
1 to 4
1
1 to 1000
s
0 to 200
s
1 to 1000
s
---
---
---
---
---
---
---
---
---
---
1 to 50
/hr.
---
---
---
---
0.00 to 20.00
x CT
0.00 to 20.00
x CT
0.00 to 20.00
x CT
---
---
0.00 to 20.00
x CT
---
---
0.05 to 20.00
x CT
0.05 to 20.00
x CT
1 to 1000
s
0.00 to 300.00
s
---
---
---
---
0 to 100
%
0 to 100
%
0 to 100
%
0 to 100
%
0 to 100
%
0.00 to 300.00
s
---
---
---
---
750/760 FEEDER MANAGEMENT RELAY – COMMUNICATIONS GUIDE
TYPE
DEFAULT
F1
10 s
F1
100 min.
F56
Disabled
F2
1.0 s
F2
3.0 s
F30
Disabled
F2
0.0 s
F30
Disabled
F94
Scheme 1
F30
Disabled
F1
1
F1
60 s
F1
10 s
F1
30 s
F57
None
F57
None
F57
None
F30
Disabled
F38
Disabled
F1
25
F57
None
F30
Disabled
F3
17.00 x CT
F3
18.00 x CT
F3
19.00 x CT
F30
Disabled
F3
20.00 x CT
F30
Disabled
F3
1.00 x CT
F3
1.00 x CT
F1
10 s
F3
0.50 s
F80
Active Group
F59
None blocked
F1
0%
F1
0%
F1
0%
F1
0%
F1
0%
F3
3.00 s
F80
Active Group
F59
None blocked