MEMORY MAP
Table 3: Modbus Memory Map (Sheet 31 of 40)
ADDR
1
Analog Threshold 2 Pickup Type
18AC
18AD
Analog Threshold 2 Dropout Ratio
ANALOG INPUT RATE 1 (read/write setpoints)
18B0
Analog In Rate 1 Function
18B1
Analog In Rate 1 Relays
18B2
Analog In Rate 1 Pickup
18B3
Analog In Rate 1 Delay
ANALOG INPUT RATE 2 (read/write setpoints)
18B8
Analog In Rate 2 Function
18B9
Analog In Rate 2 Relays
18BA
Analog In Rate 2 Pickup
18BB
Analog In Rate 2 Delay
ANALOG OUTPUT 1 (read/write setpoints)
18C0
Analog Output 1 Parameter
18C1
Analog Output 1 Minimum
18C2
Analog Output 1 Maximum
ANALOG OUTPUT 2 (read/write setpoints)
18C4
Analog Output 2 Parameter
18C5
Analog Output 2 Minimum
18C6
Analog Output 2 Maximum
ANALOG OUTPUT 3 (read/write setpoints)
18C8
Analog Output 3 Parameter
18C9
Analog Output 3 Minimum
18CA
Analog Output 3 Maximum
ANALOG OUTPUT 4 (read/write setpoints)
18CC
Analog Output 4 Parameter
18CD
Analog Output 4 Minimum
18CE
Analog Output 4 Maximum
ANALOG OUTPUT 5 (read/write setpoints)
18D0
Analog Output 5 Parameter
18D1
Analog Output 5 Minimum
18D2
Analog Output 5 Maximum
ANALOG OUTPUT 6 (read/write setpoints)
18D4
Analog Output 6 Parameter
18D5
Analog Output 6 Minimum
18D6
Analog Output 6 Maximum
ANALOG OUTPUT 7 (read/write setpoints)
18D8
Analog Output 7 Parameter
18D9
Analog Output 7 Minimum
18DA
Analog Output 7 Maximum
ANALOG OUTPUT 8 (read/write setpoints)
18DC
Analog Output 8 Parameter
18DD
Analog Output 8 Minimum
18DE
Analog Output 8 Maximum
OVERFREQUENCY (read/write setpoints)
18E0
Overfrequency Function
18E1
Overfrequency Relays
18E2
Overfrequency Pickup
18E3
Overfrequency Delay
TRIP COUNTER (read/write setpoints)
1900
Trip Counter Function
1901
Trip Counter Relays
1 2 3 4 5 6 7 8 9 10 11 12 13
For explanation of Table footnotes, see the Memory Map Notes at the end of this table.
4 - 36
DESCRIPTION
CHAPTER 4: MODBUS MEMORY MAP
RANGE
UNITS
---
---
2 to 20
%
---
---
---
---
–1000.0 to 1000.0
Units / hr.
0 to 60000
s
---
---
---
---
–1000.0 to 1000.0
Units / hr.
0 to 60000
s
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
20.00 to 65.00
Hz
0.0 to 6000.0
s
---
---
---
---
750/760 FEEDER MANAGEMENT RELAY – COMMUNICATIONS GUIDE
TYPE
DEFAULT
F85
Over
F1
5%
F38
Disabled
F57
None
F5
10.0 µA/hr.
F1
0 s
F38
Disabled
F57
None
F5
10.0 µA/hr.
F1
0 s
F77
Disabled
F78
0
F78
0
F77
Disabled
F78
0
F78
0
F77
Disabled
F78
0
F78
0
F77
Disabled
F78
0
F78
0
F77
Disabled
F78
0
F78
0
F77
Disabled
F78
0
F78
0
F77
Disabled
F78
0
F78
0
F77
Disabled
F78
0
F78
0
F38
Disabled
F57
None
F3
60.50 Hz
F2
5.0 s
F38
Disabled
F57
None