GE 750 Manual page 34

Feeder management relay
Hide thumbs Also See for 750:
Table of Contents

Advertisement

MEMORY MAP
Table 3: Modbus Memory Map (Sheet 9 of 40)
ADDR
0301
Phase B RMS Current
0302
Phase C RMS Current
0303
Percent of Load-to-Trip
0304
Ground Current
0305
A-N RMS Voltage
0306
B-N RMS Voltage
0307
C-N RMS Voltage
0308
A-B RMS Voltage
0309
B-C RMS Voltage
030A
C-A RMS Voltage
3
Reserved for Polarizing Current
030B
030C
Average Current
030D
Average Line Voltage
030E
Average Phase Voltage
030F
Neutral Current
FREQUENCY AND THREE-PHASE POWER (read only actual values)
2, 12
Three-Phase Real Power
0310
2, 12
Three-Phase Reactive Power
0311
2, 12
Three-Phase Apparent Power
0312
0313
Three-Phase Power Factor
0314
System Frequency
1
System Frequency Decay Rate
0315
1
Auto Ranging Power / Energy Multiplier
0316
SYNCHRONIZING VOLTAGE (read only actual values)
0318
Synchronizing RMS Voltage
0319
Synchronizing RMS Voltage Frequency
031A
Synchronizing Voltage Difference
031B
Synchronizing Phase Difference
031C
Synchronizing Frequency Difference
031D
Synchronizing Voltage Angle
ENERGY USE (read only actual values)
2
Positive Watthours (2 words)
0320
0322
Positive Watthour Cost (2 words)
2
Negative Watthours (2 words)
0324
0326
Negative Watthour Cost (2 words)
2
Positive Varhours (2 words)
0328
2
Negative Varhours (2 words)
032A
032C
Energy Use Data Last Reset (2 words)
LAST DEMAND (read only actual values)
0330
Last Phase A Current Demand
0331
Last Phase B Current Demand
0332
Last Phase C Current Demand
2
Last Real Power Demand
0333
2
Last Reactive Power Demand
0334
2
Last Apparent Power Demand
0335
MAXIMUM DEMAND (read only actual values)
0340
Maximum Phase A Current Demand
0341
Maximum Phase A Current Date (2 words)
0343
Maximum Phase A Current Time (2 words)
0345
Maximum Phase B Current Demand
1 2 3 4 5 6 7 8 9 10 11 12 13
For explanation of Table footnotes, see the Memory Map Notes at the end of this table.
4 - 14
DESCRIPTION
CHAPTER 4: MODBUS MEMORY MAP
RANGE
UNITS
0 to 65535
A
0 to 65535
A
0 to 2000
%
0 to 65535
A
0.00 to 655.35
kV
0.00 to 655.35
kV
0.00 to 655.35
kV
0.00 to 655.35
kV
0.00 to 655.35
kV
0.00 to 655.35
kV
---
---
0 to 65535
A
0.00 to 655.35
kV
0.00 to 655.35
kV
0 to 65535
A
–30000 to 30000
kW
–30000 to 30000
kvar
0 to 30000
kVA
–0.99 to +1.00
---
0.00 to 65.00
Hz
–10.00 to 10.00
Hz/s
1 to 100
---
0.00 to 655.35
kV
0.00 to 65.00
Hz
0.00 to 655.35
kV
0 to 359
°
0.00 to 65.00
Hz
0 to 359
° Lag
0 to 4e9
kWh
0 to 4e9
$
0 to 4e9
kWh
0 to 4e9
$
9
kvarh
0 to 4 × 10
9
kvarh
0 to 4 × 10
---
---
0 to 65535
A
0 to 65535
A
0 to 65535
A
–30000 to 30000
kW
–30000 to 30000
kvar
0 to 30000
kVA
0 to 65535
A
---
---
---
---
0 to 65535
A
750/760 FEEDER MANAGEMENT RELAY – COMMUNICATIONS GUIDE
TYPE
DEFAULT
F1
---
F1
---
F1
---
F1
---
F3
---
F3
---
F3
---
F3
---
F3
---
F3
---
---
---
F1
---
F3
---
F3
---
F1
---
F86
---
F86
---
F86
---
F6
---
F3
---
F6
---
F1
---
F3
---
F3
---
F3
---
F1
---
F3
---
F1
---
F86
---
F7
---
F86
---
F7
---
F86
---
F86
---
F23
---
F1
---
F1
---
F1
---
F86
---
F86
---
F86
---
F1
---
F23
---
F22
---
F1
---