Technical information
Model Greenline
Emitted /Supplied output at 0/35ºC (¹) kW
Emitted /Supplied output at 0/50ºC (¹) kW
Nominal flow distr. system
Nominal flow collector system
Permitted ext. press. drop distr. syst. kPa
Permitted ext. press. drop coll. syst.
Electrical supply
Electric boiler in three steps E-model
Fuse size D-model
Fuse size E-model depending
on the electric boiler output
9.0 kW
15.75 kW
11.3 kW
18.0 kW
27.0 kW
Recommended setting motor cutout
Compressor
Starting current (LRA)
Max outgoing heating transfer fluid
Refrigerant quantity (R407C)
Connection, heating medium
Connection, cooling medium
Dimensions (WxDxH)
Weight
(¹) Output data at 0/35ºC and 0/50ºC are stated in accordance with the European standard EN255. Additional heat not included.
Table of selected output in display 5.2
The table shows the output available for various selections in display P5.2. If e.g. you have chosen
2/3 the output is in two steps. The first step is 5.6 kW and the second is 9.0kW.
Model
Max output at 1/3
E14 and E16
E20
E25

Sensor table

The table shows the resistance of all sensors at different temperatures.
k Ω Ω Ω Ω Ω
Temperature ºC
-40
154,30
-35
111,70
-30
81,70
-25
60,40
-20
45,10
-15
33,95
-10
25,80
-5
19,77
0
15,28
D14-E14 D16-E16 D20-E20 D25-25
13,8/3,2
13,5/4,6
l/s
0,46
l/s
0,79
43
kPa
75
kW
15,75
5,6 / 9,0 / 15,75 5,6 / 9,0 / 15,75 6,7 / 11,3 / 18,0 9,0 / 18,0 / 27,0
AT
16
AT
25
AT
35
AT
-
AT
-
AT
-
A
9,6
A
59,5
ºC
kg
1,8
Cu
28
Cu
35
mm
600x600x1500
kg
180
5.6 kW
6.7 kW
9.0 kW
Temperature ºC
5
10
15
20
25
30
35
40
45
15,8/3,6
21/5,1
15,4/5,2
20/7,1
0,53
0,69
0,91
1,16
41
45
74
63
400V, N3 three-phase 50 HZ
15,75
18
16
20
25
-
35
-
-
35
-
50
-
-
10,8
13,7
Scroll
70,5
98
55
2,2
3,7
28
35
35
42
700x750x1500
180
210
Max output at 2/3
9.0 kW
11.3 kW
18.0 kW
k Ω Ω Ω Ω Ω
Temperature ºC
11,90
9,33
7,37
5,87
4,70
3,79
3,07
2,51
2,055
61
D35
25,5/6,3
35,2/8,6
41,5/10,4
24,8/8,7
34,7/12
40,9/14,3
0,85
1,19
1,45
2,03
40
65
60
50
27
-
25
35
-
-
-
-
-
-
50
-
63
-
16,4
23,4
120
175
4,2
7,5
35
35
42
42
700x750x1500
210
230
Max output at 3/3
15.75 kW
18.0 kW
27.0 kW
k Ω Ω Ω Ω Ω
50
1,696
55
1,405
60
1,170
65
0,980
70
0,824
75
0,696
80
0,590
85
0,503
90
0,430
D40
1,41
2,39
62
47
-
35
-
-
-
-
-
26,5
175
8,5
35
42
230