Technical information

Technical information

The heat pump's factory settings

The table shows the factory settings for all the settings that can be
changed by the installer.
Menu Setting
1.1
Temp. incr. / decr.
1.2
Temp. fi ne-tune
1.3
Adapting the heat curve
1.4
Heat curve hysteresis
1.5
Mix. valve incr/decr
1.6
Mix. valve fi ne-tune
1.7
Adapting the mixing valve curve
1.8
Mixing valve curve neutral zone
1.9
Mixing valve curve max at GT4
1.10
Setting the room temperature
1.11
Setting the room sensor infl uence
1.12
Setting of holiday function
1.13
Remote control temperature
1.14
Setting of summer disconnection
2.1
Number of hours for extra hot water
2.2
Interval for hot water peak
2.3
Setting of hot water temperature
2.4
Setting of DHW hysteresis
4.1
Clock setting HP accord. to clock
4.1.1
Setting level heat pump +/-
4.2
Clock setting additional heat according to clock
4.3
Clock setting hot water according to clock
5.2
Select connection capacity electric cassette
5.4
Select function only add. heat
5.5
Select function additional heat
5.7
Select external controls
5.10
Select operation alt. P2
5.11
Select operation alt. P3
8.1
Setting additional heat timer

Sensor table

The table shows all sensor resistance
at different temperatures.
Factor y setting
4
4
60º
20º
5
0 days
Not active
18º
0 hours
Not active
51º
Not active
Not active
Not active
2/3
off
yes
0
P2 cont. operat.
P3 with comp.
60 minutes
40
Temperature (
kΩ
ºC)
-40
154.300
-35
111.700
-30
81.700
-25
60.400
-20
45.100
-15
33.950
-10
25.800
-5
19.770
0
15.280
5
11.900
10
9.330
15
7.370
20
5.870
25
4.700
30
3.790
35
3.070
40
2.510
45
2.055
50
1.696
55
1.405
60
1.170
65
0.980
70
0.824
75
0.696
80
0.590
85
0.503
90
0.430