Technical Information; Technical Information - Heat Pump Module - IVT AirModule E 15 Installer's Manual

230v 1n / 400v 3n
Table of Contents

Advertisement

Technical information

4
Technical information
4.1

Technical information - heat pump module

Electrical information
Power supply
Recommended fuse size
Immersion heater in steps
Heating installation
3)
Connection
Maximum operating pressure
Minimum operating pressure
Expansion vessel
External available pressure
Minimum flow
Circulation pump model
Flow max. temperature, booster
only
General
Hot water cylinder volume
Maximum operating pressure on
tap DHW circuit
Material
IP rating
Dimensions (WxDxH)
Weight
Table 3 heat pump module with immersion heater
1) 3N AC 50 Hz
2) 1N AC 50 Hz
3) See Connections in safety assembly
4) This depends on the type of heat pump, see tab. 11
6
Unit
1)
V
400
1)
A
16
kW
3/6/9
Cu 28
kPa
kPa
L
kPa
L/s
0.36
Grundfos UPM2 25-75 PWM
°C
L
MPa
mm
kg
E9
2)
/230
2)
/ 50
250
50
14
4)
85
190
1
Stainless steel 1.4521
IP X1
600x660x1800
135
E15
1)
400
1)
25
3/6/9/12/15
Cu 28
250
50
14
4)
0.59
Wilo Stratos Para 25/1-11 PWM
85
190
AirModule 6 720 813 268(2014/10)

Hide quick links:

Advertisement

Table of Contents
loading