Particle filter: The particle filters, which are connected on both the hot and cold sides of the heat
pump, protect the heat exchangers from dirt. Sometimes these filters may get clogged and cause
malfunctions.
Do this when checking: Shut down the heat pump with the on/off button on the control panel.
Close the valve and unscrew the sealing cover. Check for dirt in the filter. If necessary, remove the
circlip that retains the filter. The simplest way to do this is by using pliers. Remove the filter and flush
it clean with water. Refit the filter, circlip and cover. Open the valve and start the heat pump. Note
that the particle filters in the E14 and E16 series are mounted inside the heat pump (pos 1). On the
cold side the filter is mounted outside the heat pump.
Particle filter
Where the various components are situated (models 14-16)
The pages, If something goes wrong and Maintaining your heat pump, show various positions in
your heat pump. The picture shows the location of the various components.
The picture is of the E series.
Cleanable particle filter with
shut off lever valve.
Reset, motor cutout com-
pressor.
Reset circuit breaker heat
pump.
Reset circuit breaker
electric water heater.
Pos 1
Pos 2
Pos 3
Pos 4
Pos 5
Reset button for overheat
protection on the electric heater
elements.
Pos 6 (Emergency op, E series)
Turn the thermostat wheel to the
right to manually activate the
electric boiler.
Set the 3-way valve to the
intermediate position by pushing
the grey switch downwards at
the same time as it is pressed
inwards.
WARNING! Must not be
activated during normal opera-
tion.
Pos 7
Sight glass