Control Unit Rego 600; Installer/Service Settings; Installer/Service Menu; Joint Displays For Operating Modes A, B And C - IVT Greenline D14 Manual To Installation, Commissioning And Maintenance

Table of Contents

Advertisement

Control unit Rego 600

If you are an installer, note that you can find certain information about the operation of the control
unit in the sections intended for the end user. It is therefore important for installers to read the
guide before putting the heat pump into service.

Installer/service settings

As the installer, "Installer / Service" gives you access to all the menu displays that the end user has at
customer levels 1 and 2. Note that the menu display is connected to the selected operating mode.
You will never see displays that concern anything else but the selected operating mode.

Installer/Service menu

By holding down the "Menu" button for 10 seconds and then
enter "Menu" you will come to settings for installers or service
companies. The Menu display is divided into lines and each
display has a number to make it easy to find. You will auto-
matically return to level 1 again after 30 seconds.

Joint displays for operating modes A, B and C

Line 1
Temperature settings
Heat curve
adjust. (break)
Return
Select
Line 4
Clock setting
Clock sett. add heat
accord. to clock 4.2
Return
Select
Line 5
Commiss./Service
Select operation
mode
A B C
Return
Select
Commiss./Service
Manual operation of
all functions
Return
Select
Here you can "break" the heat curve up or down for each
fifth degree of outdoor temperature. You can e.g. do a
1.3
temporary increase on the curve at 0°C outdoor tempera-
ture.
You can block the additional heat totally during certain
times of day. Instructions are found in the chapter on clock
controls in the increased customer level.
Here you choose the operational mode you require. Con-
tinuous operation is the factory setting.
5.1
When controlling functions you can manually start and stop
pumps and valves etc here.
5.3
020301
Heat
Installer only. As an end-user you
must never go into this level!
51
Rego600
I/S
12:00:00
Fr
Info
Menu
WARNING!

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents