Checking Switch Continuity - Yamaha YFM700RV 2009 Service Manual

Table of Contents

Advertisement

CHECKING SWITCH CONTINUITY

8 - 2
EBS01028
CHECKING SWITCH CONTINUITY
Check each switch for continuity with the
pocket tester. If the continuity reading is incor-
rect, check the wiring connections and if nec-
essary, replace the switch.
CAUTION:
_
Never insert the tester probes into the cou-
pler terminal slots 1. Always insert the
probes from the opposite end of the cou-
pler, taking care not to loosen or damage
the leads.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
NOTE:
_
• Before checking for continuity, set the pocket
tester to "0" and to the "Ω × 1" range.
• When checking for continuity, switch back
and forth between the switch positions a few
times.
The terminal connections for switches (e.g.,
main switch, engine stop switch) are shown in
an illustration similar to the one on the left.
The switch positions a are shown in the far
left column and the switch lead colors b are
shown in the top row in the switch illustration.
NOTE:
_
"
" indicates a continuity of electricity
between switch terminals (i.e., a closed circuit
at the respective switch position).
The example illustration on the left shows
that:
There is continuity between the switch termi-
nals for the red and brown switch leads when
the switch is set to "ON".
+
ELEC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yfm700rv 2006

Table of Contents