The Setup menu

Accessing the
1
Setup menu
2
Changing weld-
1
ing parameters
2
3
4
Exiting the Setup
1
menu
Parameters for
Parameter
MMA welding
Use the welding process button to select the process whose Setup parameters
are to be changed:
MMA welding
MMA welding with cellulose electrode
TIG welding
+
Press the setting value and welding process buttons together
After releasing the buttons, the code for the first parameter in the Setup menu is
displayed
Turn the adjusting dial to select the required parameter
Press the adjusting dial to display the preset value of the parameter
Turn the adjusting dial to change the value
The new value becomes effective immediately
Exception: when restoring the factory settings, press the adjusting dial after
changing the value to activate the new value.
Press the adjusting dial to return to the list of parameters
Press the setting value or
Welding process button to exit from the Setup menu
Description
Starting current duration
for the SoftStart / HotStart function
Factory setting: 0.5 seconds
Anti-stick
When the anti-stick function is active, the arc is
extinguished after 1.5 seconds in the event of a
short circuit (sticking of the electrode)
Factory setting: ON (activated)
Break voltage (U cut off)
Used to specify at which arc length the welding
process is completed.
The welding voltage increases as the length of the
arc increases. The arc is extinguished when it
reaches the voltage specified here.
Factory setting: 45 V
Range
Unit
0.1 - 1.5 Seconds
On
OFF
25 - 80 Volt
33