Temperature Monitoring; Overcharge Protection - Fronius AccuPocket 150/400 Operating Instructions Manual

Rod electrode power source
Hide thumbs Also See for AccuPocket 150/400:
Table of Contents

Advertisement

Temperature
Temperature monitoring prevents the battery from being charged or discharged if it is out-
monitoring
side the permitted temperature range.
If the battery falls below the permitted temperature range:
-
-
-
If the battery exceeds the permitted temperature range:
-
-
Overcharge pro-
Once the battery has been fully charged, the charger turns off automatically and switches
tection
to conservation charging mode.
In this mode the device can remain connected to the charger for any period of time.
"cold" appears on the temperature indicator
neither welding nor charging is possible
After approx. 5 seconds the temperature indicator goes out and operations in pure
welding mode is possible again.
The charging operation can be carried out at a battery temperature of -10°C and
above
"hot" appears on the temperature indicator
no welding or charging operation possible until the temperature indicator goes out
25