Banner GM-FA-10J Original Instructions Manual page 21

Gate monitoring safety
Table of Contents

Advertisement

GM-FA-10J Gate Monitoring Safety Module
LED
Fault ON
Input 1 ON or OFF
Input 2 ON or OFF
Output OFF
Power FLASHING
Fault FLASHING
Input 1 OFF
Input 2 OFF
Output OFF
Power ON
Fault ON
Input 1 ON
Input 2 ON
Output FLASHING
Power ON
Fault FLASHING
Input 1 OFF
Input 2 OFF
Output OFF
EC Declaration of Conformity
Banner Engineering Corp.
9714 Tenth Avenue North
Minneapolis, MN 55441-5019 USA
We herewith declare that GM-FA-10J Gate Monitoring Safety Module for industrial control is in conformity with the provisions of the Ma-
chinery Directive (Directive 98/37/EEC), and all essential Health and Safety Requirements have been met.
R. Eagle / Engineering Manager
10/16/2009
Download the complete EC Declaration of Conformity as a PDF file at Banner website.
Banner Engineering Corp Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of
shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned
to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse,
abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (IN-
CLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND
WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Fault, Probably Cause, and Procedures
a. 2-channel simultaneity > 3 seconds (configured for 2-channel
operation)
b. Channel simultaneity > 1 second (NO/NC did not switch within 1
second)
See
Configuration
on page 3 for description of complementary
switching and 2-channel operation.
DIP-SWITCH ERROR
a. DIP-switch settings are incorrect; Bank A does not match Bank
B
See
Configuration
on page 10 for DIP-switch configuration.
OPEN RESET FAULT
a. Y1/Y2 open when configured for Auto Reset
See
Configuration
on page 10 for Manual/Auto Reset information.
INTERNAL FAULT (See
Repairs
a. Incorrect check sum
b. Internal relay failure (e.g., welded contact due to inductive load
arcing.)
c. Low input power
d. Other internal fault
on page 19)