Inputs
Each switch or sensor must have a normally closed
contact and a normally open contact capable of switch-
ing 20 to 50 mA @ 15 to 30V dc.
Reset switch: 20 mA @ 12V dc, hard contact only
Max. external resistance between terminals S11/S12,
S11/S13, S21/S22 and S21/S23: 270 ohms each.Max.
external resistance between terminals S11/S12, S11/
S13, S21/S22 and S21/S23: 270 ohms each.
Environmental
Vibration Resistance
10 to 55 Hz @ 0.35 mm displacement per IEC
60068-2-6
Operating Conditions
Temperature: 0° to +50°C (+32° to 122°F)
Maximum Relative Humidity: 90% @ +50°C (non-con-
densing)
Dimensions
22.5 mm
(0.89")
S13
S12
S11
A1
13
23
Y1
Power
84.0 mm
Fault
K1
(3.31")
In 1
K2
14 24
In 2
Machine
Safety
Output
GM-FA-10I
Y2
14
24
A2
S23
S21
S22
Magnetic Switch Models
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
1-Channel operation: infinite
Certifications
Design Standards
CE: Cat. 4 PL e, per EN ISO 13849-1; SIL 3 per IEC
61508 and IEC 62061
118.0 mm
(4.65")
Figure 10. Dimensions
Figure 11. Label
GM-FA-10J Gate Monitoring Safety Module