GM-FA-10J Gate Monitoring Safety Module
Magnet/Sensor Pair
* 9 m (30 ft) cables are available for magnet sensors by adding suffix "w/30" to the model number (e.g., SI-MAG1SM w/30).
† Cable opposite see
Figure 13. SI-MAG1SMCO Sensor
†† 90° orientation (see
Direction of Approach for SI-MAG1xx Sensor/Magnet Pairs
Magnetic Switch Specifications
Switching Elements
Three pole-stable reed switches
Repeat Switching Accuracy
±0.1 mm (±0.004 inches)
Construction
Epoxy-encapsulated circuit in polyamide housing
Environmental Rating
NEMA 4X, IEC IP67
Switching Capacity
30V dc max @ 0.25W (27 Ω fuse resistor in-line, each
channel)
Operating Temperature
–5° to +70°C (+23° to +158°F)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Magnet Sensor*
Coded Magnet
SI-MAG1MM
SI-MAG1MM90††
SI-MAG1SM
SI-MAG1SMCO†
SI-MAG1MMHF
SI-MAG2SM
SI-MAG2MM
SI-MAG3SM
SI-MAG3MM
on page 16)
Sensor Cable
3 m (10 ft)
on page 17)
Connections
Integral PVC-jacketed 3 m (10 ft) 4-wire cable.
Cable O.D. is 5 mm (0.2 inches).
Wires are 24 AWG (0.25 mm²).
Hardware
All mounting hardware is supplied by user. Use of per-
manent fasteners or locking hardware is recommended
to prevent loosening or displacement of the actuator
and switch body. Mounting holes in the magnet and
sensor accept M4 (#6) hardware (see
Dimensions
on page 16).
Application Note
The sensor/magnet pair must be mounted a minimum
distance of 15 mm (0.6 inches) from any magnetized or
ferrous materials. Multiple SFA-IMB1 (used with SI-
MAG1xx) and SFA-IMB2 (used with SI-MAG2xx) can
be used as spacers.
Switching Distance
Min. ON
Max. OFF
3 mm (0.12 in-
14 mm (0.55
ches)
inches)
8 mm (0.31 in-
16 mm (0.63
ches)
inches)
4 mm (0.16 in-
8 mm (0.32 in-
ches)
ches)
3 mm (0.12 in-
7 mm (0.28 in-
ches)
ches)
Magnetic Switch