Danfoss PVG 120 Service Manual page 15

Proportional valve group
Hide thumbs Also See for PVG 120:
Table of Contents

Advertisement

Service Manual
Installation
Max. tightening torques – Mounting Threads in SAE J 518c Flanges
Port
P
A/B
T
Max. tightening torques – UN and UNF Connection Threads – O-ring Boss Port
Ports
P
Sealing
1 5/16 in-12 UN
/Thread
O-ring
160 N•m
[1410 in•lbs]
PVG 120 Proportional Valve Group
Size
1 in
3/4 in
1 in
A/B
1 1/16 in-12 UN
120 N•m
[1060 in•lbs]
Ports identification
520L0247 • Rev JA • May 2014
Threads
M12, 18 deep
7/16 - 14 UNC 0.7" deep
M10, 17 deep
3/8 - 16 UNC 0.7" deep
M10, 17 deep
3/8 - 16 UNC 0.7" deep
Max. tightening torques
T
PA/PB
1 5/16 in-12 UN
½ in-20 UNF
160 N•m
30 N•m
[1410 in•lbs]
[270 in•lbs]
Tightening torque
68 N•m
[600 lbf·in]
45 N•m
[400 lbf·in]
45 N•m
[400 lbf·in]
MA
LS, LX, PP
½ in-20 UNF
¾ in-20 UNF
30 N•m
60 N•m
[270 in•lbs]
[530 in•lbs]
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents