For Standard 800 MHz Rebanded Systems, you need to set Band Plan 1
and Band Plan 2 as follows:
Band Plan Lower Base Freq Upper Base Freq Offset Polarity Spacing
1
2
Select Plan 1-6 Select for each Band Plan.
Set Base Freq
Input Lower - Enter the lower base frequency and press E/yes.
Input Upper - Enter the upper base frequency and press E/yes.
Set Offset
Input Offset - Enter the offset and press E/yes.
Select Polarity - Scroll to + (default) or - and press E/yes.
Set Spacing - Scroll to the step size and press E/yes.
Press Menu to return and repeat for each band plan as needed.
Set Frequencies
New Frequency/Edit Frequency. Enter the frequency and press E/yes.
For EDACS and LTR sites only:
Input LCN enter the LCN number and press E/yes.
Delete Frequency
At Confirm Delete? press E/yes or .no.
Set Modulation
the Site. The default setting is Auto (NFM for FM frequencies).
Auto, NFM, or FM
See also Scan Modulation.
Set Attenuator
on this Site by about 20dBs The default setting is Off.
On or Off
See also Scan Attenuation.
Set Avoid
This determines whether a Site will be scanned or not. Temporary
Avoid cancels when you cycle power. The default setting is Stop Avoiding.
Temporary Avoid, Stop Avoiding, or Avoid
See also Scan Avoids.
50
Site Options
851.025
851.0125
This is where you program trunking frequencies for the Site.
(no P25/1TR) This setting selects the modulation used for
This setting controls whether the scanner attenuates signals
854.000
868.9875
440
+
25 kHz
0
+
25 kHz