Service Codes; Safety; General; Displaying Status Codes - Fronius Primo 3.0-1 Service Manual

Grid-connected inverter
Table of Contents

Advertisement

Available languages

Available languages

Service codes

Safety

General

These service codes help to localise and - where possible - rectify faults with the device
directly on site. The individual service codes are subdivided into service classes.
The following information is given for every service code:
-
-
IMPORTANT! Software may only be updated after consulting the Solar Electronics hotline.
The need for the update will be clarified in advance depending on the serial number and
firmware version.
Displaying status
The inverter performs a system self diagnosis that automatically detects many faults that
codes
may occur and shows them on the display. This means you are promptly made aware of
malfunctions in the inverter and the photovoltaic system, or of any installation or operating
faults.
If the system self diagnosis has detected a specific fault, the associated status code will be
shown on the display.
IMPORTANT! Status codes may sometimes appear briefly as a result of the inverter's con-
trol response. If the inverter then continues working with no sign of any problem, this
means that there was no fault.
Total failure of the
If the display fails to come on some time after sunrise:
display
-
*
Class 1 service
Class 1 status codes generally only arise momentarily and are caused by the public grid.
codes
The initial response of the inverter in this case is to disconnect itself from the grid. The grid
is subsequently checked for the stipulated monitoring period. If no further problem has
been detected by the end of this period, then the inverter will resume feeding energy into
the grid.
WARNING! An electric shock can be fatal. Before opening the device:
-
If applicable, turn the mains switch to the -O- position
-
Unplug the device from the mains
-
Disconnect the inverter from the DC side
-
Using a suitable measuring instrument, ensure that electrically charged parts
(e.g. capacitors) are fully discharged
-
Restrict access to the working area
-
Take steps to ensure the metallic surfaces of the device cannot be touched
-
Suitable protective clothing and equipment must be worn when carrying out
the test or the repair
the reason the service code is being displayed
the relevant troubleshooting measure
Check the AC voltage ON the inverter connections:
the AC voltage must be 230 V (+ 10 % / - 5 %)*.
The mains voltage tolerance depends on the country setup
91

Advertisement

Chapters

Table of Contents
loading

Table of Contents