Replacing the RECERBO display PC board

Replacing the RE-
Removing the RECERBO:
CERBO display
PC board
Installing the RECERBO:
(1)
(2)
(2)
(4)
(3)
WARNING! An electric shock can
be fatal. Observe the safety rules
(see the beginning of the "Safety"
section).
Take the inverter out of the wall bra-
1
cket, open it and remove the Datama-
nager card (see "Opening and closing
the device" and "Replacing the Data-
manager card" sections)
Remove the external fan cable from
2
the cable guide (1)
Push the RECERBO holder locking de-
3
vices (2) upwards
Remove the RECERBO module
4
NOTE! Take care not to damage
any of the components when car-
rying out the next two steps.
Take the holder (3) off the RECERBO
5
Break the device data unit (4) off the
6
faulty RECERBO