Fronius Primo 3.0-1 Service Manual page 137

Grid-connected inverter
Table of Contents

Advertisement

Available languages

Available languages

(6)
Clean the heat sink
a)
b)
NOTE! If you are returning the PrimoPS power PC board:
-
Clean the modules using a clean cloth
-
Take the PCM film out of the small parts kit
-
Position the PCM film on the modules and smooth it out
-
Remove the protective film
Installing the PrimoPS:
(8)
Remove the four 4x9 mm TX20 screws
5
(6) in the modules
Separate the PrimoPS PC board from
6
the heat sink by inserting a screwdriver
into the "Remove PCB" hole (7) and
pressing in the direction of the arrow
Remove the power PC board from
7
above
(7)
IMPORTANT!
-
When cleaning the heat sink, ensure
that you remove all heat transfer medi-
um residues.
-
Clean the heat sink using a clean cloth
only.
-
Do not scratch the heat sink or damage
it in any other way during cleaning.
Clean the heat sink
1
a)
Heat sink with heat transfer medi-
um residues
b)
Clean heat sink
Remove the two blister packs (8) from
1
the modules of the new PrimoPS pow-
er PC board
IMPORTANT! The step below must be car-
ried out.
Place the blister pack onto the faulty
2
power PC board and return it to Froni-
us.
137