Internal
clock
4-14
Figure 4-11 illustrates the use of C/T0 on the 8254 on board 1 to divide
the rate of the master clock by the programmed count; this allows you to
synchronize conversions on board 1 to a rate different from that of the
master board. Note that when you use C/T0 to divide the rate of the
master clock, C/T0 must be configured for counter/timer mode 2 (rate
generator mode). Refer to page 2-21 or to your 8254 documentation for
more information.
Board 0
(Master)
Pin 5
OUT1
Figure 4-11. Dividing the Rate of the Master Clock
Board 1
÷
C/T0
count
Pin 24
INT_IN /
XCLK
Pin 3 - OUT0
Pin 2
CLK0