Download Print this page

Fisher & Paykel DD24DI Installation Manual page 18

Double dishdrawer
Hide thumbs Also See for DD24DI:

Advertisement

!5
E
-
CONNECT THE KNOCK-TO-PAUSE MODULE
TO THE CONTROLLER
Ensure the Knock-To-Pause Module
Cable is connected to the UI1 Port.
Repeat for the other drawer.
!5
G
-
ATTACH CUSTOM PANELS TO PRODUCT
2
1
17
!5
INSTALLING CUSTOM FRONT DRAWER PANELS
Controller
Push the Custom Panel on to
the drawer and reinsert the
side pins on each side.
Repeat for the other drawer.
Side Pin
2
!5
F
-
RECONNECT THE EARTH WIRE TO THE
PANEL BRACKET
!5
H
-
ADJUST CUSTOM PANEL HEIGHT TO
ALIGN CABINETRY GAPS
With the front panels fitted, insert
an appropriately sized Philips
screwdriver into the hole above the
side pin and rotate the panels up or
down to align the gaps
in your cabinetry.
Repeat on the other side if necessary.
Each panel has a maximum travel of
1/16" (2mm) up or down.
IMPORTANT!
Ensure that you maintain a minimum
of 5/16" (8mm) ventilation gap
between the upper and lower panels.
WARNING!
Electrical Shock Hazard
To earth the panel bracket, connect the earth
wire from the product to one of the tabs.
Any custom metal component (e.g. handle)
that extends past the rubber seal must be
earthed too.
Failure to follow these warnings may result
in electrical shock, injury or fire.
Reconnect the
Earth Wire to the
Panel bracket.
Repeat for the
other drawer.
+ or -
1/16" (2mm)

Advertisement

loading

This manual is also suitable for:

Dd24dtiDd24dhtiDouble dishdrawer dd24diDouble dishdrawer dd24dtiDouble dishdrawer dd24dhti