3.5

Power Supply

• 9.6V rechargeable NiMH battery pack
• Line Voltage: 85 to 256V / 50-60Hz
Minimum Battery Charge Life (per NF EN 61557-2)
Test Voltage
500V
1000V
2500V
5000V
Average Battery Life: The operating time will be 15 days or 3 weeks, based
upon a 10 minute long PI measurement.
Recharge Time:
Charging must be done between 20 and 30°C
6 hours for 100% capacity (10 hours if the battery is completely drained)
0.5 hours for 10% capacity (charge life: 2 days approximately)
NOTE: It is possible to recharge the batteries while performing insulation
measurements provided that the values measured are higher than 20MΩ.
In this case, the recharging time is higher than 6 hours and depends on
the frequency of the measurements.
3.6

Environmental Specifications

Operating Range:
14° to 104°F (-10° to 40°C) during recharging of batteries
14° to 131°F (-10° to 55°C) during measurement
10 to 80% RH
Storage: -40 to 158°F (-40 to 70°C); 10 to 90% RH
Altitude: <2000m
Use indoors or outdoors
Megohmmeter Model 6505
Nominal Charge
500kΩ
1MΩ
2.5MΩ
5MΩ
Number of Measurements
5s on nominal charge (with 25s pause between
each measurement)
6500
5500
4000
1500