3. Maintenance and Inspection

3.3.2 The Operation Panel Unit (NCG-169)

All failures of the Recording Control Unit are indicated by the Operation Panel Unit
as an error code.
Symptom
All LEDs blink and
the ALARM BUZZER
sounds.
RECORDING LED
fails to light.
ERROR CODE:
"01__" lights up.
ERROR CODE:
"31__" lights up.
ERROR CODE:
"32__" lights up.
ERROR CODE:
"00__" lights up.
Causes
The software of the Recording Control
Unit lost control.
Faulty wiring between the Recording
Control Unit and the Operation Panel
Unit.
The Recording Control Unit is off.
The power is not supplied to the
Protective Capsule Unit.
Stop manually the recording of data
onto the Protective Capsule Unit.
Faulty wiring between the Recording
Control Unit and the Protective Capsule
Unit
Fault in the Recording Control Unit
Fault in the Protective Capsule Unit
Initial value of HEADING is not
registered yet.
The CARD STOP SWITCH is left on.
No CF CARD is loaded.
Fault in the Recording Control Unit
Fault in the CF CARD
Fault in the Recording Control Unit
Mismatching in the information
between the Recording Control Unit and
the Protective Capsule Unit.
Faulty wiring between the Recording
Control Unit and the Protective Capsule
Unit.
Fault in the Recording Control Unit
Fault in the Protective Capsule Unit
Reboot the Recording Control Unit.
Check the wiring between the
Recording Control Unit and the
Operation Panel Unit.
Check the switchboard.
Turn on the Power Supply Unit.
Press the REC START SWITCH on
the Main Control Board in the
Recording Control Unit and restart
the recording of data.
Check the Connection Box.
Reboot the Recording Control Unit
and see if it works normally. If it
does not work, contact us.
Enter the initial value of HEADING
Press the CF CARD EJECT BUTTON
and remove it from the Main Control
Board. Then put it back again.
Insert a CF CARD into the CARD
slot of the Main Control Board.
Reboot the Recording Control Unit
and see if it works normally. If it
does not work, contact us.
Press the CF CARD EJECT BUTTON
and remove it from the Main Control
Board. Then put it back again.
Reboot the Recording Control Unit
and see if it works normally. If it
does not work, contact us.
Press and hold the REC START
SWITCH for ten seconds.
Check the Connection Box.
Reboot the Recording Control Unit
and see if it works normally. If it
does not work, contact us.
40
Actions to be taken