2. Place the equipment to a Table
Attach 4 rubber feet on the parts marked on the bottom of this equipment as below. Refer to
"Open space required around this equipment" before deciding the place for this equipment.
Mark for rubber feet
Safety installation instruction:
1) Multiple pile
The maximum 5 IP-920E/DC can be piled under the environment condition
specified. Please install considering the maintenance-ability. When
IP-920E/DC is piled, please fix them to avoid falling (do not cover the air
intake.). See Section 2.1.4, "Open space required around this equipment"
for the installation space.
2) rack mounting
a) When IP-920E/DC is installed in a closed or multi-unit rack, the
operating ambient temperature inside of the rack environment may be
greater than room ambient. Therefore, the consideration should be
given to operate in the environment compatible with the specifications
in Appendix 2.2 "Environment Specifications."
The consideration for adjustment of the air condition like air
-
circulation should be given to prevent the internal rack ambient
from exceeding the maximum operating ambient temperature of
IP-920E/DC.
The maximum operating ambient temperature for IP-920E/DC:
-
55°C.