Transmitter scale factor / K-factor (P013)

Level measurement

When the process value (PV) is a level measurement in meters, feet, or inches, this
parameter converts the level measurement into alternative units before being output.
Enter a value of 1.0 if alternative units are not required.

Volume measurement

When the PV is a volume measurement from a standard non-linear-shaped tank e.g.
cylinder or sphere, use this parameter to enter the volume of the ideal shaped tank
(Figure
11).
When the PV is a volume measurement from a regular-shaped tank e.g. square or
rectangular, use this parameter to enter the volume change per unit of the base unit.
When the PV is a volume measurement from an irregular-shaped tank, use this
parameter to enter the maximum volume relating to the Profile Height
See also the Special Plot section on
Figure 11. Volume from a cylinder/sphere
A. Rosemount 3107 or 3108
B. Rosemount 3490 Series Control Unit
C. 4–20mA/HART
D. Bottom Reference (P010)
E. Profile Height (P014)
Open channel measurement
When the PV is the flow rate in a standard open channel, use this parameter to enter
the scale factor ('k' term) in a flow rate calculation. See
profile.
When the PV is the flow rate in an irregular-shaped open channel, use this parameter to
enter the maximum flow rate. See also the Special Plot section on
the irregular-shaped channel.
16
page 19
A
D
P013 = Full Volume of Ideal Cylindrical or
Spherical Tank of Constant Diameter P014
for defining the irregular-shaped tank.
B
C
page 14
July 2016
(page
17).
for selecting a flow
page 19
for defining

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount ultrasonic 3108

Table of Contents