MicroCloud
5037MC-H12TRF
USER'S MANUAL
Revision 1.0b

Advertisement

Table of Contents
loading

Summary of Contents for Supero MicroCloud

  • Page 1 Проконсультироваться и купить данное оборудование вы можете в компании «АНД-Системс» адрес: 125480, г.Москва, ул.Туристская, д.33/1; site: https://andpro.ru тел: +7 (495) 545-4870 email: info@andpro.ru При обращении используйте промокод AND-PDF и получите скидку. UPER ® UPER ERVER MicroCloud 5037MC-H12TRF USER’S MANUAL Revision 1.0b...
  • Page 2 The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
  • Page 3: About This Manual

    SuperServer 5037MC-H12TRF. Installation and maintenance should be performed by experienced technicians only. The SuperServer 5037MC-H12TRF is a 12-node, MicroCloud server system based on the SC939H-R1K63B 3U chassis and 12 X9SCE-F motherboards. Please refer to our web site for an up-to-date list of supported processors.
  • Page 4 UPER ERVER 5037MC-H12TRF User's Manual Chapter 5: Advanced Motherboard Setup Chapter 5 provides detailed information on the X9SCE-F motherboard, including the locations and functions of connectors, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the motherboard.
  • Page 5 Preface Notes...
  • Page 6: Table Of Contents

    UPER ERVER 5037MC-H12TRF User's Manual Table of Contents Chapter 1 Introduction Overview ......................1-1 Motherboard Features ..................1-2 Processors ...................... 1-2 Memory ......................1-2 SATA ......................1-2 Rear I/O Ports ....................1-2 Graphics ......................1-2 IPMI ......................... 1-3 Server Chassis Features ................1-4 System Power ....................
  • Page 7 Table of Contents Warning Defi nition ................... 4-1 Installation Instructions ..................4-4 Circuit Breaker ....................4-5 Power Disconnection Warning ................ 4-6 Equipment Installation ..................4-8 Restricted Area ....................4-9 Battery Handling .................... 4-10 Redundant Power Supplies ................4-12 Backplane Voltage ..................4-13 Comply with Local and National Electrical Codes ........
  • Page 8 UPER ERVER 5037MC-H12TRF User's Manual 5-15 Onboard Battery .................... 5-20 Chapter 6 Advanced Chassis Setup Static-Sensitive Devices .................. 6-1 Precautions ..................... 6-1 Removing the Chassis Cover ................. 6-2 Corresponding Nodes and Fans ..............6-3 Removing and Installing Motherboard Nodes ..........6-4 Installing/Removing Hard Drives ..............
  • Page 9: Chapter 1 Introduction

    Chapter 1 Introduction Overview The SuperServer 5037MC-H12TRF is a 12 node, MicroCloud server system com- prised of the SC939H-R1K63B 3U chassis and 12 X9SCE-F motherboards. Please refer to our web site for information on operating systems that have been certifi ed for use with the 5037MC-H12TRF (www.supermicro.com).
  • Page 10: Motherboard Features

    UPER ERVER 5037MC-H12TRF User's Manual Motherboard Features The 5037MC-H12TRF includes a total of 12 X9SCE-F single processor mother- boards, which are based on the Intel C204 PCH chipset. Each motherboard con- stitutes a node in the system. Below are the main features of the X9SCE-F. (See Figure 1-1 for a block diagram of the chipset.) Processors Each X9SCE-F supports a single Intel E3-1200 v2 Series up to 69W (87W condi-...
  • Page 11: Ipmi

    Chapter 1: Introduction Figure 1-1. Intel C204 Chipset: System Block Diagram Note: This is a general block diagram. See Chapter 5 for details. IPMI IPMI (Intelligent Platform Management Interface) is a hardware-level interface speci- fi cation that provides remote access, monitoring and administration for Supermicro server platforms.
  • Page 12: Server Chassis Features

    UPER ERVER 5037MC-H12TRF User's Manual Server Chassis Features The following is a general outline of the main features of the SC939H-R1K63B server chassis. System Power The SC939H-R1K63B features a redundant 1620W high-effi ciency power supply comprised of two separate power modules. This power redundancy feature allows you to replace a failed power supply without shutting down the system.
  • Page 13: Contacting Supermicro

    Chapter 1: Introduction Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands Tel:...
  • Page 14 UPER ERVER 5037MC-H12TRF User's Manual Notes...
  • Page 15: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation Overview This chapter outlines the procedure to set up your system and install it to a rack. If your system is not already fully integrated with a motherboard, processors, system memory etc., please turn to the chapter or section noted in each step for details on installing specifi...
  • Page 16: Warnings And Precautions

    UPER ERVER 5037MC-H12TRF User's Manual • This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with Visual Display Units. Warnings and Precautions Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are fully extended to the fl...
  • Page 17: Rack Mounting Considerations

    Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera- ture (Tmra).
  • Page 18: Installing The System Into A Rack

    UPER ERVER 5037MC-H12TRF User's Manual Installing the System into a Rack Use the procedure below for installing the system to a rack. 1. Decide where you want to place the system into the rack (see "Rack Mount- ing Considerations" in the previous section). 2.
  • Page 19 Chapter 2: Server Installation Figure 2-2. Securing the Rails to the Rack Note: These handles are optional and need only be installed when mounting the system into a short rack. When mounting into a deep rack, they are unnecessary and regular screws should be used instead of thumbscrews. 6.
  • Page 20 UPER ERVER 5037MC-H12TRF User's Manual Figure 2-3. Installing to the Rack Note: this fi gure is for illustrative purposes only. Always install servers to the bot- tom of a rack fi rst. Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the fl...
  • Page 21: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview LEDs are included on the serverboard nodes and the power supply modules to keep you informed of their operational status. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take. Motherboard Nodes Power Button/LED The main power button on each of the nodes functions as both an on/off switch and...
  • Page 22: Power Supply Modules

    UPER ERVER 5037MC-H12TRF User's Manual Figure 3-1. Node LED Indicator Node LED Figure 3-2. Power Supply Module LED Indicator Power Module Power Supply Modules Power Module LED Each of the power supply modules has its own LED to indicate the status of the module.
  • Page 23: Chapter 4 Standardized Warning Statements For Ac Systems

    Chapter 4: Warning Statements for AC Systems Chapter 4 Standardized Warning Statements for AC Systems About Standardized Warning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance.
  • Page 24 UPER ERVER 5037MC-H12TRF User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
  • Page 25 Warning Statements for AC Systems ‫ﺟﺴﺪﻳﺔ‬ ‫ﺍﺻﺎﺑﺔ‬ ‫ﺗﺘﺴﺒﺐ ﻓﻲ‬ ‫ﺣﺎﻟﺔ ﻳﻤﻜﻦ ﺃﻥ‬ ‫ﺍﻧﻚ ﻓﻲ‬ ‫ﺧﻄﺮ‬ ‫ﻳﻌﻨﻲ‬ ‫ﻫﺬﺍ ﺍﻟﺮﻣﺰ‬ !‫ﺗﺤﺬﻳﺮ‬ ‫ﺍﻟﺪﻭﺍﺋﺮ‬ ‫ﺑﺎﻟﻤﺨﺎﻁﺮ ﺍﻟﻨﺎﺟﻤﺔ ﻋﻦ‬ ‫ﻦ ﻋﻠﻰ ﻋﻠﻢ‬ ، ‫ﻛ‬ ‫ﻣﻌﺪﺍﺕ‬ ‫ﺗﻌﻤﻞ ﻋﻠﻰ ﺃﻱ‬ ‫ﻗﺒﻞ ﺃﻥ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫ﺣﻮﺍﺩﺙ‬ ‫ﺃﻱ‬ ‫ﻭﻗﻮﻉ‬ ‫ﻤﻨﻊ‬ ‫ﻟ‬ ‫ﺍﻟﻮﻗﺎﺋﻴﺔ‬...
  • Page 26: Installation Instructions

    UPER ERVER 5037MC-H12TRF User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 設置手順書 システムを電源に接続する前に、 設置手順書をお読み下さい。 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
  • Page 27: Circuit Breaker

    Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. サーキッ ト ・ ブレーカー この製品は、 短絡 (過電流) 保護装置がある建物での設置を前提としています。 保護装置の定格が250 V、...
  • Page 28: Power Disconnection Warning

    UPER ERVER 5037MC-H12TRF User's Manual 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A.
  • Page 29 Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Attention Le système doit être débranché...
  • Page 30: Equipment Installation

    UPER ERVER 5037MC-H12TRF User's Manual Equipment Installation Warning! Only trained and qualifi ed personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、 交換、 またはサービスを許可 されています。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifi...
  • Page 31: Restricted Area

    Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalifi ceerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
  • Page 32: Battery Handling

    UPER ERVER 5037MC-H12TRF User's Manual ‫אזור עם גישה מוגבלת‬ !‫אזהרה‬ ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ .('‫כלי אבטחה בלבד )מפתח, מנעול וכד‬ ‫ﻣﺤﻈﻮﺭﺓ‬ ‫ﻣﻨﺎﻁﻖ‬ ‫ﻟﺘﺮﻛﻴﺒﻬﺎ ﻓﻲ‬ ‫ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ‬ ‫ﺗﺨﺼﻴﺺ‬ ‫ﺗﻢ‬ ،‫ﺃﺩﺍﺓ ﺧﺎﺻﺔ‬ ‫ﻣﻦ ﺧﻼﻝ ﺍﺳﺘﺨﺪﺍﻡ‬ ‫ﻓﻘﻂ‬...
  • Page 33 Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
  • Page 34: Redundant Power Supplies

    UPER ERVER 5037MC-H12TRF User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります。 ユニッ トの電源を切るためには、 すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
  • Page 35: Backplane Voltage

    Chapter 4: Warning Statements for AC Systems ‫ﺍﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ‬ ‫ﺑﻮﺣﺪﺍﺕ‬ ‫ﻋﺪﺓ ﺍﺗﺼﺎﻻﺕ‬ ‫ﺠﻬﺎﺯ‬ ‫ﺍﻟ‬ ‫ﻳﻜﻮﻥ ﻟﻬﺬﺍ‬ ‫ﻗﺪ‬ ‫ﺍﻟﻜﻬﺮﺑﺎء‬ ‫ﻋﻦ‬ ‫ﻮﺣﺪﺓ‬ ‫ﺍﻟ‬ ‫ﻟﻌﺰﻝ‬ ‫ﻛﺎﻓﺔ ﺍﻻﺗﺼﺎﻻﺕ‬ ‫ﻳﺠﺐ ﺇﺯﺍﻟﺔ‬ 경고! 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에 전원을...
  • Page 36: Comply With Local And National Electrical Codes

    UPER ERVER 5037MC-H12TRF User's Manual ‫מתח בפנל האחורי‬ !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬ .‫העבודה‬ ‫ﺍﻟﻠﻮﺣﺔ‬ ‫ﺃﻭﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻋﻠﻰ‬ ‫ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ‬ ‫ﻣﻦ‬ ‫ﺧﻄﺮ‬ ‫ﻫﻨﺎﻙ‬ ‫ﻫﺬﺍ ﺍﻟﺠﻬﺎﺯ‬ ‫ﺧﺪﻣﺔ‬ ‫ﻛﻦ ﺣﺬﺭﺍ ﻋﻨﺪ‬ ‫ﻳﻌﻤﻞ‬ ‫ﺍﻟﻨﻈﺎﻡ‬ ‫ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ‬ 경고! 시스템이...
  • Page 37: Product Disposal

    Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ ‫הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫התקנת‬ ‫ﺍﻟﻤﺘﻌﻠﻘﺔ‬ ‫ﺍﻟﻤﺤﻠﻴﺔ ﻭﺍﻟﻮﻁﻨﻴﺔ‬ ‫ﻘﻮﺍﻧﻴﻦ‬ ‫ﻳﺠﺐ ﺃﻥ ﻳﻤﺘﺜﻞ ﻟﻠ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬...
  • Page 38: Hot Swap Fan Warning

    UPER ERVER 5037MC-H12TRF User's Manual ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
  • Page 39 Chapter 4: Warning Statements for AC Systems 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
  • Page 40: Power Cable And Ac Adapter

    UPER ERVER 5037MC-H12TRF User's Manual Power Cable and AC Adapter Warning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fi re. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certifi...
  • Page 41 Chapter 4: Warning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie. Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifi...
  • Page 42 UPER ERVER 5037MC-H12TRF User's Manual Notes 4-20...
  • Page 43: Chapter 5 Advanced Motherboard Setup

    Chapter 5: Advanced Motherboard Setup Chapter 5 Advanced Motherboard Setup This chapter covers the steps required to connect the data and power cables and install add-on cards. All motherboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference. Remember to completely close the chassis when you have fi...
  • Page 44: Unpacking

    UPER ERVER 5037MC-H12TRF User's Manual Unpacking The motherboard is shipped in antistatic packaging to avoid electro static discharge. When unpacking the board, make sure the person handling it is static protected. Motherboard Installation/Removal The X9SCE-F motherboards have been preinstalled into carriers to simplify install- ing and removing the nodes from the SC939H-R1K63B chassis.
  • Page 45: Processor And Heatsink Installation

    Chapter 5: Advanced Motherboard Setup Processor and Heatsink Installation Notes: • When changing the CPU in a node, always power down the node fi rst and remove it from the chassis. Make sure that you install the CPU into its socket before you install the CPU heatsink.
  • Page 46 UPER ERVER 5037MC-H12TRF User's Manual 3. Use your thumb and your index fi nger to hold the CPU at the top center edge and the bottom center edge of the CPU. 4. Align the CPU key (the semi-circle cutouts) against the socket keys. Once aligned, carefully lower the CPU straight down to the socket.
  • Page 47: Installing A Heatsink

    Chapter 5: Advanced Motherboard Setup CPU properly installed Load lever locked into place. Make sure "A" points are under B Installing a Heatsink 1. With the node removed, remove the air shroud. 2. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied.
  • Page 48: Installing Memory

    UPER ERVER 5037MC-H12TRF User's Manual Installing Memory Caution! Exercise extreme care when installing or removing DIMM modules to prevent any possible damage to the DIMMs or their sockets How to Install Memory 1. Insert the desired number of DIMMs into the memory slots in the following order: DIMMA2, then DIMMB2, DIMMA1, DIMMB1.
  • Page 49: Installing And Removing Dimms

    Chapter 5: Advanced Motherboard Setup Installing and Removing DIMMs Position the DIMM module's bottom key so that it aligns with the receptive point on the slot. Notches Push a lock/release tab to the Release release position. Make sure that the side notches of the DIMM module aligns with the lock/release tab of the slot as Release...
  • Page 50: Memory Population Guidelines

    UPER ERVER 5037MC-H12TRF User's Manual Memory Population Guidelines 1. When installing memory modules, the DIMM slots should be populated in the following order: DIMMA2, DIMMB2, DIMMA1 and DIMMB1 2. Always use DDR3 DIMM modules of the same size, type and speed. 3.
  • Page 51 Chapter 5: Advanced Motherboard Setup Note: The PCI slot shields protect the motherboard and its components from EMI and aid in proper ventilation, so make sure there is always a shield covering each unused slot. Expansion Card Riser Card Figure 5-4. Installing the Expansion Card Note: The node and motherboard shown above are examples.
  • Page 52: Motherboard Details

    UPER ERVER 5037MC-H12TRF User's Manual Motherboard Details Figure 5-5. X9SCE-F Layout DIMMA1 DIMMA2 Socket H2 Socket H2 LGA 1155 LGA 1155 DIMMB1 DIMMB2 5-10...
  • Page 53: X9Sce-F Quick Reference

    Chapter 5: Advanced Motherboard Setup X9SCE-F Quick Reference Jumper Description Default Setting JPME2 ME Manufacturing Mode Pins 1-2 (Normal) JBT1 CMOS Reset See Section 5-11 JWD1 Watch Dog Timer Pins 1-2 (Reset) JPME1 ME Recovery Mode Select Pins 1-2 (Normal) JPG1 Onboard VGA Enable/Disable Pins 1-2 (Enabled)
  • Page 54: Connector Defi Nitions

    UPER ERVER 5037MC-H12TRF User's Manual Connector Defi nitions IF + POWER This edge connector, located on the opposite end of the motherboard from the I/O back panel, is used to connect the motherboard to the backplane of the server chassis. Through this connector, the motherboard will receive its power and com- municate with the rest of the system (hard drives, warning lamps, etc).
  • Page 55: 5-10 I/O Port Defi Nitions

    Chapter 5: Advanced Motherboard Setup 5-10 I/O Port Defi nitions KVM Port The KVM port supports two USB devices and VGA and UART interfaces. Please attach a compatible KVM connector/ switch to this port. IPMI Port A dedicated IPMI LAN port is located next to the KVM port to provide dedi- cated network connection for IPMI 2.0.
  • Page 56: 5-11 Jumper Settings

    UPER ERVER 5037MC-H12TRF User's Manual 5-11 Jumper Settings Explanation of Jumpers To modify the operation of the mother- board, jumpers can be used to choose Connector between optional settings. Jumpers Pins create shorts between two pins to change the function of the connector. Pin 1 is identifi...
  • Page 57 Chapter 5: Advanced Motherboard Setup VGA Enable/Disable (JPG1) VGA Enable/Disable Jumper Settings JPG1 allows the user to enable the Jumper Setting Defi nition onboard VGA connector (through the Pins 1-2 Enabled KVM). Close pins 1~2 to enable the Pins 2-3 Disabled VGA.
  • Page 58: 5-12 Onboard Indicators

    UPER ERVER 5037MC-H12TRF User's Manual 5-12 Onboard Indicators Activity LED Link LED IPMI IPMI Dedicated LAN Port A dedicated IPMI LAN port is located IPMI LAN Link Speed LED (Left) & on the I/O back panel. The yellow LED Connection Activity LED (Right) on the right indicates activity, while the Color/State Defi...
  • Page 59: 5-14 Installing Software

    Chapter 5: Advanced Motherboard Setup 5-14 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. After accessing the ftp site, go into the CDR_Images directory and locate the ISO fi...
  • Page 60: Superdoctor Iii

    UPER ERVER 5037MC-H12TRF User's Manual SuperDoctor III The SuperDoctor® III program is a web-based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The SuperDoctor III program allows you to monitor the environment and operations of your system.
  • Page 61 Chapter 5: Advanced Motherboard Setup Figure 5-8. SuperDoctor III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/soft- ware/SuperDoctorIII.cfm. For Linux, we recommend that you use the SuperDoctor II application instead.
  • Page 62: 5-15 Onboard Battery

    UPER ERVER 5037MC-H12TRF User's Manual 5-15 Onboard Battery Please handle used batteries carefully. Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfi ll. Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly.
  • Page 63: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte- nance on the SC939H-R1K63B chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows.
  • Page 64: Removing The Chassis Cover

    UPER ERVER 5037MC-H12TRF User's Manual Removing the Chassis Cover Figure 6-1. Removing the Chassis Cover Removing the Chassis Cover 1. Disconnect the chassis from any power source. 2. Remove the three screws which secure the top cover to the chassis as il- lustrated above.
  • Page 65: Corresponding Nodes And Fans

    Chapter 6: Advanced Chassis Setup Corresponding Nodes and Fans The 5037MC-H12TRF contains 12 individual motherboards contained in separate nodes. Each three nodes share a common fan. Figure 6-2. Corresponding Nodes and Fans Fan 1 Fan 2 Fan 3 Fan 4 Corresponding Nodes and Fans Node Nodes 1, 2, 3...
  • Page 66: Removing And Installing Motherboard Nodes

    UPER ERVER 5037MC-H12TRF User's Manual Removing and Installing Motherboard Nodes Release Tab Handle Figure 6-3. Removing a Node The system comes features twelve removable nodes. Each node contains an in- dividual motherboard and hard drives mounted on a sled, which allows it to easily be installed and removed from the chassis.
  • Page 67: Installing/Removing Hard Drives

    Chapter 6: Advanced Chassis Setup Installing/Removing Hard Drives The hard drives are installed directly to the sled, which must fi rst be removed from the system. For this reason, hard drives are not hot-swappable. Either two 3.5" or four 2.5" hard drives can be installed in each sled (node). An optional kit is required to install the 2.5"...
  • Page 68 UPER ERVER 5037MC-H12TRF User's Manual Figure 6-5. Installing/Removing 2.5" Hard Drives (Optional) Note: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro Web site at http://www.supermicro.com/products/nfo/storage.cfm...
  • Page 69: System Fans

    Chapter 6: Advanced Chassis Setup System Fans Four 9-cm fans circulate air through the chassis to lower the internal temperature. These fans are designed to be easily changed, with no tools required and no need to remove any other parts inside the chassis. In the event of a fan failure, follow the instructions below to replace it.
  • Page 70: Power Supply

    UPER ERVER 5037MC-H12TRF User's Manual Power Supply The system includes a redundant 1620 watt, high-effi ciency power supply. The two power supply modules are auto-switching capable, which enables them to automatically sense and operate at a 100V to 240V input voltage. An amber light is illuminated on the power supply when the power is off.
  • Page 71: Chapter 7 Bios

    Chapter 7: BIOS Chapter 7 BIOS Introduction This chapter describes the AMI BIOS Setup Utility for the X9SCD-F/X9SCD+-F/ X9SCD+-HF motherboard. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens.
  • Page 72: How To Start The Setup Utility

    UPER ERVER 5037MC-H12TRF User's Manual How to Start the Setup Utility Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility. From the main menu, you can access the other setup screens.
  • Page 73 Chapter 7: BIOS System Overview: The following BIOS information will be displayed: System Time/System Date Use this option to change the system time and date. Highlight System Time or Sys- tem Date using the arrow keys. Enter new values through the keyboard. Press the <Tab>...
  • Page 74: Advanced Setup Confi Gurations

    UPER ERVER 5037MC-H12TRF User's Manual Advanced Setup Confi gurations Use the arrow keys to select Boot Setup and hit <Enter> to access the submenu items:  BOOT Feature Quiet Boot This feature allows the user to select the bootup screen display between POST messages and the OEM logo.
  • Page 75 Chapter 7: BIOS Wait For 'F1' If Error Select Enabled to force the system to wait until the 'F1' key is pressed if an error occurs. The options are Disabled and Enabled. Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture"...
  • Page 76 UPER ERVER 5037MC-H12TRF User's Manual Hardware Prefetcher (Available when supported by the CPU) If set to Enabled, the hardware prefetcher will prefetch streams of data and instruc- tions from the main memory to the L2 cache in the forward or backward manner to improve CPU performance.
  • Page 77 Chapter 7: BIOS power consumption and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disabled and Enabled. P-STATE Coordination This feature selects the type of coordination for the P-State of the processor. P-State is a processor operational state that reduces the processor's voltage and frequency.
  • Page 78 UPER ERVER 5037MC-H12TRF User's Manual Memory Frequency This feature allows the user to select the memory speed. Under normal conditions, please set this to Auto. The options are Auto, Force DDR-800, Force DDR-1067, Force DDR-1333, and Force DDR-1600.  Integrated I/O Confi guration This item displays the current North Bridge Revision.
  • Page 79 Chapter 7: BIOS  South Bridge Confi guration This item displays the current South Bridge Revision. USB Functions This feature allows the user to decide the number of onboard USB ports to be enabled. The Options are Disabled and Enabled. Legacy USB Support (available if USB Functions above is Enabled) Select Enabled to use Legacy USB devices.
  • Page 80 UPER ERVER 5037MC-H12TRF User's Manual SATA Port0~Port5 This item displays the information detected on the installed SATA drives on the particular SATA port. AHCI Mode The following items are displayed when AHCI Mode is selected: Aggressive Link Power Management This feature Enables or Disables Aggressive Link Power Management support for Cougar Point B0 stepping and later.
  • Page 81: Console Redirection Settings

    Chapter 7: BIOS  PCIe/PCI/PnP Confi guration This feature allows the user to set the PCI/PnP confi gurations for the following items: PCI ROM Priority In case of multiple Option ROMs (Legacy and EFI-compatible), this feature specifi es what ROM to launch. The options are Legacy ROM and EFI Compatible ROM. PCI Latency Timer This feature sets the latency Timer of each PCI device installed on a PCI bus.
  • Page 82 UPER ERVER 5037MC-H12TRF User's Manual Parity: None, Even, Odd, Mark, or Space Stop Bits: 1 or 2 Flow Control: None or Hardware RTS/CTS Recorder Mode: Disabled or Enabled Resolution 100x31: Disabled or Enabled Legacy OS Redirection Resolution: 80x24 or 80x25 SOL Console Redirection Use this feature to enable console redirection for SOL (Serial Over LAN).
  • Page 83 Chapter 7: BIOS Data Bits: 8 or 7 Parity: None, Even, Odd, Mark, or Space Stop Bits: 1 or 2  Hardware Health Confi guration Fan Speed Control Mode This feature allows the user to decide how the system controls the speeds of the onboard fans.
  • Page 84 UPER ERVER 5037MC-H12TRF User's Manual Suspend Mode This setting allows you to confi gure the ACPI (Advanced Confi guration and Power Interface) sleep state for your system when it is in the Suspend mode. The options are Suspend Disabled, S1 (POS), and S3 (STR). S3 (STR) is the deepest sleep state in these options.
  • Page 85: Event Logs

    Chapter 7: BIOS Event Logs  Change Smbios Event Log Settings The following options are available: Smbios Event Log Change this item to enable or disable all features of the Smbios Event Logging during boot. The options are Enabled and Disabled. Erase Event Log This option erases all logged events.
  • Page 86: Ipmi Confi Guration

    UPER ERVER 5037MC-H12TRF User's Manual METW The Multiple Event Time Window (METW) defi nes number of minutes must pass between duplicate log events before MECI is incremented. This is in minutes, from 0 to 99. View Smbios Event Log Displays the Smbios Event Log stored in memory. IPMI Confi...
  • Page 87 Chapter 7: BIOS BMC Network Confi guration  Set this feature to confi gure the IPMI LAN adapter with a network address. Update IPMI LAN Confi guration Select Yes to update the IPMI LAN confi guration. The options are Yes and No. Confi...
  • Page 88: Boot Settings

    UPER ERVER 5037MC-H12TRF User's Manual Boot Settings Use this feature to confi gure Boot Settings:  Boot Options Priority This feature allows the user to specify which devices are boot devices and the order of priority from which the systems boots from during startup. Boot Option #1, Boot option #2, Boot Option #3, etc The settings are Built-in EFI Shell, [any detected boot device] and Disabled.
  • Page 89: Security Settings

    Chapter 7: BIOS Security Settings • If the Administrator password is defi ned ONLY - this controls access to the BIOS setup ONLY. • If the User's password is defi ned ONLY - this password will need to be entered during each system startup or boot, and will also have Administrator rights in the setup.
  • Page 90: Exit Options

    UPER ERVER 5037MC-H12TRF User's Manual Exit Options Select the Exit tab from the BIOS Setup Utility screen to enter the Exit BIOS Setup screen. Save Changes and Exit When you have completed the system confi guration changes, select this option to leave the BIOS Setup Utility and reboot the computer, so that the new system confi...
  • Page 91 Chapter 7: BIOS Save As User Defaults To set this feature, select Save as User Defaults from the Exit menu and press <Enter>. This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature, select Restore User Defaults from the Exit menu and press <En- ter>.
  • Page 92 UPER ERVER 5037MC-H12TRF User's Manual Notes 7-22...
  • Page 93: Appendix A Post Error Beep Codes

    Appendix A: POST Error Beep Codes Appendix A POST Error Beep Codes This section lists POST (Power On Self Test) error beep codes for the AMI BIOS. POST error beep codes are divided into two categories: recoverable and terminal. This section lists Beep Codes for recoverable POST errors. Recoverable POST Error Beep Codes When a recoverable type of error occurs during POST, BIOS will display a POST code that describes the problem.
  • Page 94 UPER ERVER 5037MC-H12TRF User's Manual Notes...
  • Page 95: Appendix B System Specifi Cations

    Appendix B: System Specifi cations Appendix B System Specifi cations Processors Each node supports one Intel E3-1200 v2 Series up to 69W (or 87W conditional), Intel 2nd Generation Core i3 or Intel Pentium family processor in an LGA 1155 socket Note: Please refer to our web site for a complete listing of supported processors.
  • Page 96 UPER ERVER 5037MC-H12TRF User's Manual System Cooling Four 9-cm system fans System Input Requirements AC Input Voltage: 100 - 240V AC auto-range Rated Input Current: 11.5 - 5.5A max Rated Input Frequency: 50 to 60 Hz Power Supply Rated Output Power: 1000W @ 100-120V, 1200W @ 120-140V, 1620W @ 180-240V (Part# PWS-1K63S-1R) Rated Output Voltages: +12V (84A @ 1000W, 100A @ 1200W, 135A @ 1620W), +5Vsb (4A)
  • Page 97 Appendix B: System Specifi cations Notes...
  • Page 98 UPER ERVER 5037MC-H12TRF User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be reasonably expected to result in signifi...