System Status And Performance - Planet G.SHDSL Bridge/Router GRT-402 User Manual

G.shdsl bridge/router
Hide thumbs Also See for G.SHDSL Bridge/Router GRT-402:
Table of Contents

Advertisement

PLANET Technology Corp.
PPPoA/PPPoE protocols must work with NAT/PAT. Please refer to section 3.11.3 NAT/PAT for details.

3.13 System Status and Performance

Use the "status" command to display GRT series activities. To see a list of
applications and interfaces that provide status, enter:
admin# status ?
shdsl <CR>
wan <CR>
route <CR>
To display specific information, for example, for the SHDSL interface status
and performance, enter:
admin# status shdsl
<SHDSL Status>
SHDSL mode
Bitrate
Tx Power
Current SNR Margin
Attenuation
CRC Error Count
SHDSL Remote Side Status
Current SNR margin
Attenuation
CRC Error Count
These statistics are:
• CRC error count — The cyclic redundancy check error count.
• Attenuation —The difference in decibels (dB) between the power level
received at the near end versus the power level transmitted from the far end.
• Signal-to-Noise (SNR) Margin — The SNR margin represents the amount of
increased received signal (in decibels) relative to the noise power level that the
unit is designed to tolerate without disconnecting from the network.
To display status of WAN ports, enter:
admin# status wan
WAN
IP address
Show SHDSL status
Show WAN interface status
Show routing table
:SHDSL CPE Side
:512kbps
:13.5dBm
:10.8dB
:35.8dB
:0
:10dB
:35dB
:0
/
NetMask
- -
63
GRT-101/401/402 User's Manual
VPI/ VCI
Enc
Protocol Active

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grt-101Grt-401

Table of Contents