Installing A Model 10933 Or 10934A 300 W Dc Power Supply In A Summit X460 Series Switch; Required Tools And Materials - Extreme Networks Summit X150 Series Hardware Installation Manual

Hide thumbs Also See for Summit X150 Series:
Table of Contents

Advertisement

Chapter 6: Installing Summit Family Switches
Installing a Model 10933 or 10934A 300 W DC Power
Supply in a Summit X460 Series Switch
CAUTION
Make sure that the DC power supply circuit is not overloaded. Use proper over-current protection, such as
a circuit-breaker, to prevent over-current conditions. You may use up to a 30-Amp breaker.
To install a DC power supply in a Summit X460 switch, perform the following tasks in the order listed:
1 Prepare the power cables and ground cable by attaching the provided connection lugs to the cables
(see
"Preparing the Cables" on page
2 Insert the power supply into the Summit X460 series switch (see
page
251.)
3 Connect the ground (see
4 Have a qualified licensed electrician connect the power supply to the DC source voltage (see
"Connecting the Power Supply to the DC Source Voltage" on page
5 Energize the DC circuit.

Required Tools and Materials

You need the following tools and materials to install or remove a 300 W DC power supply in a
Summit X460 series switch:
Two spade terminals (Tyco part number 328281 or equivalent) for connecting the input power cables
(provided)
One ring terminal (Tyco part number 2-320561-4 or equivalent) and screw with captive lock washer
(type 6-32 UNC) for connecting the ground wire (both provided)
#14 AWG copper cable for grounding the power supply and connecting the power supply to the DC
power source
A DC power cord is not included with the 300 W DC power supply. You must provide the #14 AWG
copper cable. Recommended insulation colors are:
-
Red for the –48V connection (–)
-
Black for the –48V RTN connection (+)
-
Green or green with yellow stripe for the ground connection
Connection hardware appropriate to the installation site:
-
Hardware for connecting the power wires to the DC source
-
Hardware for connecting the ground wire to the site grounding point
Stripping tool
Crimping tool for attaching the lug to the ground wire
#1 Phillips screwdriver
Torque screwdriver and wrench or torque driver with attachments for tightening screws and nuts
ESD-preventive wrist strap
Thermal protective gloves (required for removal of a power supply)
Connection lugs for power and ground and a screw for connecting the ground wire are shipped with
the power supply.
250
251).
"Connecting the Ground Cable" on page
"Installing the Power Supply" on
252).
253).
Summit Family Switches Hardware Installation Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents