9.2b Moisture Measurement
For Integrated and Remote Pin probes
Integrated pins
Strong and reliable integrated WME pins with cap,
No effect on readings by surface moisture
Pin (% WME) 8% to 100%, readings over 30% are relative
Non-invasive (RF)
Up to 3/4" (15 mm) deep, 60 to 999 (relative),
Tolerance: ±10 relative scale
9.2c Surface Temperature
Plug in Temperature Probe Surface Temperature Probe - BLD5805
Range 32°F to 158°F (0°C to 70°C)
Accuracy at 77°F (25°C) +/- 1.3°F (0.7°C)
IR Based — With 12:1 (D:S) Ratio — With Laser Pointer
Range: 14°F to 122°F (-10°C to 50°C)
Accuracy: ±3.6°F (±2°C) @77°F (25°C)