MAG 8000 & MAG 8000 CT
8. Technical data
MAG 8000 CT MI-001 verified and labeled products at a given Q3 and Q3/Q4 = 1.25 and Q2/
Q1 = 6.3 measurering ranges se below table:
DN
50
65
(2")
(2½")
„R" Q3/Q1
25
25
3
Q4 [m
/h]
19
31
3
Q3 [m
/h]
15
25
3
Q2 [m
/h]
3.78
6.30
3
Q1 [m
/h]
0.60
1.00
DN
50
65
(2")
(2½")
„R" Q3/Q1
63
63
3
Q4 [m
/h]
19
31
3
Q3 [m
/h]
15
25
3
Q2 [m
/h]
1.50
2.50
3
Q1 [m
/h]
0.24
0.40
DN
50
65
(2")
(2½")
„R" Q3/Q1
63
63
3
Q4 [m
/h]
19
31
3
Q3 [m
/h]
15
25
3
Q2 [m
/h]
1.50
2.50
3
Q1 [m
/h]
0.24
0.40
The label is placed on the side of the encapsulation. An example of the product label is shown
below:
Note
Installation conditions for MAG 8000 CT has to be mounted in Integral (compact) and horizontal
position only, to obtain the MI-001 certification.
Battery packs must be installed with the top part in upwards direction to reach maximum capacity.
SFIDK.PS.026.D9.02
80
100
125
(3")
(4")
(5")
25
25
25
50
75
125
40
60
100
10.1
15.1
25.2
1.60
2.40
4.0
80
100
125
(3")
(4")
(5")
63
63
63
50
75
125
40
60
100
4.0
6.0
10.0
0.63
0.95
1.59
80
100
125
(3")
(4")
(5")
63
63
63
50
75
125
40
60
100
4.0
6.0
10.0
0.63
0.95
1.59
150
200
250
(6")
(8")
(10")
25
25
25
188
313
500
150
250
400
37.8
63.0
100.8
6.0
10.0
16.0
150
200
250
(6")
(8")
(10")
63
63
63
188
313
500
150
250
400
15.0
25.0
40.0
2.38
3.97
6.35
150
200
250
(6")
(8")
(10")
63
63
63
188
313
500
150
250
400
15.0
25.0
40.0
2.38
3.97
6.35
300
(12")
25
750
600
151.2
24.0
300
(12")
63
750
600
60.0
9.52
300
(12")
63
750
600
60.0
9.52