Siemens SITRANS F M MAG 8000 Operating Manual page 15

Battery operated water meter
Hide thumbs Also See for SITRANS F M MAG 8000:
Table of Contents

Advertisement

MAG 8000 & MAG 8000 CT
Device driver
Data backup
Data protection by
password
4. Commissioning
The Device Drivers are related to the meter version and is automatic selected in "Automatic"
mode. In "Manual" mode, the meter version is manually selected and the version check is
automatically made when data is uploaded or downloaded.
New device drivers are included in the latest Flow Tool program available at www.siemens.com/
flow under Battery operated Flowmeter - Tools & Downloads - SITRANS F M MAG 8000.
Meter information is stored in a internal data prom, that secure data when the power disappear.
Information like the totalizer 1 and 2, date and time, and the statistic data in the Advanced version
is stored each 10 minutes. Every 4 hours is the battery consumption calculated and remain battery
capacity is updated together with „operation time since first power up" and „battery operation
time".
The meter information is software protected by a password. The default factory password is
"1000" and can be changed after gaining access to the meter. If the password is lost, it can
be reset with a new password using the hardware key.
SFIDK.PS.026.D9.02
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans f m mag 8000 ct

Table of Contents