Parameter List - Siemens SITRANS F M MAG 8000 Operating Manual

Battery operated water meter
Hide thumbs Also See for SITRANS F M MAG 8000:
Table of Contents

Advertisement

MAG 8000 & MAG 8000 CT
Net flow output

4.3 Parameter list

FT ID
Meter
Display Parameter/data type
number
version view
1
All
M1
2
All
-
3
All
M3
4
All
M4
5
All
-
6
All
-
8
All
-
9
All
-
10
All
-
11
All
-
12
All
-
100
All
M2
101
All
O1
102
All
O2
103
All
O5
104
All
O5
4. Commissioning
The MAG 8000 has a special net pulse output that includes bi-directional flow calculations.
The example shows that over time, the net pulse output indicates the bi-directional totalizer as
calculated internally.
The same principle applies for forward and reverse flow calculation. By changing the status of
the pulse output, the internal pulse calculator will be reset.
Flow
Total accounted volume
3
[m
]
Forward/Reverse
MAG 8000 is delivered with factory settings that are not stored as default values. Because defaults
values are not present in the meter, an automatic return to factory values is not possible.
The default settings are available at www.siemens.com/flow. Navigate to Tools & Downloads
under MAG 8000.
Visible display information is indicated in the table by menu and index number. Remember to
enable displayed menus FT130.
The abbreviations used in the display menu table are: Operator menu = O, Meter menu = M,
Service menu = Se, Data Logger menu = L, Statistic menu = St, Revenue menu = R.
Application identifier
Application location
Module type
Software version
Sensor size
Vendor name
Totalizer unit
Flowrate unit
Qn
(Q3)
Product code number
Serial number
Actual date and time
Totalizer 1
Totalizer 2
Customer totalizer 3
Reset customer totalizer 3
SFIDK.PS.026.D9.02
Net totalizer in
Pulse output forward
Uni-directional mode
meter display
(Bi-directional)
Volume [m
Internal
3
Volume [m
]
calculation
0
-
10
-
−2
-
18
-
18F
Factory settings
Fix parameter or meter data that not are changeable
Indetity
Location
MLFB depended
Sensor related
Siemens
MLFB depended
MLFB depended
Sensor related
7ME6810XXXXXXXXX
7ME681 or 7ME682 XXXXXXX
XXXXXXNXXX
PS3 production date and time
0
0
0
No
Pulse output net forward
Bi-directional mode
3
]
Volume [m
Delivered
Internal
volume
calculation
0
0
10
0
−12
0
−12+20=
20
30F
Data range
Max. 14 characters. Only numbers
are visible on the display
Max. 14 characters
Basic or Advanced
x.xxPxx (x.xxPx.x)
DN 25..600(1"..24")
Siemens
Max. 10 characters
Max. 10 characters
0 to 1*10^9
year-month-day T
hours:minutes:seconds
0 to +-2*10^9
0 to +-2*10^9
0 to +-2*10^9
Yes/no
3
]
Delivered
volume
0
10
0
8
18F
21