MAG 8000 & MAG 8000 CT
5.1.3 Menu overview
5.1.4 Default display
information and
accessible display
menus
30
5. Operation
Flow tool parameter FT131 defines the default display information with selection between
•
Totalizer 1 (Index 1)
•
Totalizer 2 (Index 2)
•
Flow rate (Index 3, updated with selected measuring frequency)
•
Fault codes (Index 4)
•
Customer totalizer (Index 5 - resetable)
Default information is shown after power up and after no key operation for 10 minutes.
Flow tool parameter FT130 defines the accessible menus on the display with selection off:
•
Operator menu
•
Meter info menu
•
Service menu
•
Data logger menu
•
Statistic and leakage menu
•
Revenue menu
Disabling display of the menu data will not affect the operation of the functions.
SFIDK.PS.026.D9.02