MAG 8000 & MAG 8000 CT
FT/PDM Meter
Display Parameter/data type
number
version view
312
All
-
313
All
-
320
All
-
321
All
-
323
All
-
324
All
-
325
All
-
327
All
-
328
All
-
329
All
-
331
All
-
332
All
-
333
All
-
334
All
-
400
All
-
401
All
Se3
402
All
Se3
403
All
-
404
All
-
405
All
Se4
406
All
-
407
All
Se4
408
All
-
420
All
M5
421
All
M6
422
All
M7
423
All
-
424
All
-
425
All
-
500
All
-
501
All
-
502
All
-
505
All
-
506
All
-
507
All
-
508
All
-
509
All
Se1
510
All
Se2
512
All
-
513
All
-
514
All
-
540
All
-
541
All
-
542
All
-
550
All
-
551
All
-
552
All
-
553
All
-
560
All
-
24
4. Commissioning
Flow direction totalizer 2
Totalizer 2 changes date
Verification mode enable
Calibration date
Calibration factor
Gain correction
Sensor offset
Adjustment Factor
Low flow cut off
Filter time constant
Excitation frequency limit
Excitation frequency sensor limit Sensor related
Empty pipe detection enable
Empty pipe limit
Output A enable
Pulse A function
Amount per pulse A
Pulse width for pulse A
Output B enable
Pulse B function
Pulse B direction
Amount per pulse B
Pulse width for pulse B
Device Communication Address 1
Baudrate
Parity
Interframe space
Response delay
Reset communication driver
Latest service date
Operating hours since power up 0
Battery operating time
Power supply
Numbers of power up
Battery power
Battery change enable
Battery installation date
Actual battery capacity
Excitations no.
Power status
Transmitter temperature
Electrode impedance A
Electrode impedance B
Low medium impedance alarm
Coil current disable
Fixed flow mode enable
Fixed flow value
Flow alarm limit
Repair checksum
SFIDK.PS.026.D9.02
Factory settings
Fix parameter or meter data that not are changeable
Reverse
PS3 production date and time
No
Calibration date
Sensor related
Sensor related
Sensor related
1
0.05%
5 Tau
6.25Hz for advanced version
and 1/15Hz for basic version
Yes
25000 ohm = 20uS/cm
Yes
Forward
Sensor related
50 ms
Yes
Alarm
Reverse
Sensor related
Sensor related
19200
Even 1 stop
35
5
No
PS3 production date and time
0
Power supply level
0
MLFB depended
No
PS3 production date and time
100%
0
0
Actual degree celsius
Measured values
Measured values
0
No
No
0
1000000000
No
Data range
forward, reverse or bi-directional net flow
Yes / No
year-month-day T
hours:minutes:seconds
-2 to 2
0 to 9.9%
1 to 1000
1/15Hz, 1/5Hz, 1.5625Hz, 3.125Hz,
6.25Hz, 1/30Hz, 1/60Hz
6.25 Hz (DN25...DN200 (1"...8"))
3.125 Hz (DN250..DN600 (10"..24"))
Yes / No
0 to 2.15*10^9
Yes / No
Forward, Reverse, Forward net,
Reverse net
0-1*10^10
5 ms, 10 ms, 50 ms, 100 ms, 500 ms
Yes / No
pulse, alarm, call-up
Forward, Reverse, Forward net,
Reverse net
0-1*10^10
5 ms, 10 ms, 50 ms, 100 ms, 500 ms
1 to 32
1200, 2400, 4800, 9600, 19200, 38400
Even 1 stop, Odd 1 stop, None 2 stop,
None 1 stop
35 to 255
1 to 50 ms
Yes / No
year-month-day T
hours:minutes:seconds
hours
hours
Battery or mains power
1 to 4
batteries
Yes / No
year-month-day T
hours:minutes:seconds
100 to 0%
0: Normal operation, 1: Battery alarm.
Actual battery capacity is below battery
alarm level (% of max capacity), 2: Too
low power (enters stand by mode), 3: As
value 1 and 2 together, 4: External power
gone, 5: As value 1 and 4 together, 6: As
value 2 and 4 together, 7: As value 1 and
2 and 4 together
0-185000 ohm
0-185000 ohm
0 to 2.15*10^9
Yes / No
Yes / No
-1*10*10^9 to 1*10*10^9
0 to 1*10*9
Yes / No