LED indicator. Front panel detail *POWER LED STATUS Description Power Green LED ON when power input (DC IN on rear panel or Port 8 (UPLINK) on front panel) has valid power supplied. No power supplied. MSTRONIC CO., LTD.
Page 3
No PD is detected on this port. Yellow powered via all 4 data pairs. UPLINK (P8) Yellow powered via 2 data pairs. (1,2,3,6 or 4,5,7,8 Blanking are all acceptable). No power is detected on this port. MSTRONIC CO., LTD.
Page 4
PSE-SW8G44xx series *Power wiring 48VDC typical (44 to 57VDC) (P/N: PSE-SW8G44A4/PSE-SW8G44B4/PSE-SW8G44D4) The PoE switch family can be powered by another PoE source on port 8 (UPLINK) as a PoE repeater or extender. For PSE-SW8G44xx, the range is 44~57VDC, For PoE operation, make sure your power supply may offer at least 125W for 7x 802.3af PoE ports, or 250W for 7x 802.3at PoE ports.
Page 5
44-57VDC 44-57VDC (4 pairs output) (REAR or Port8) We recommend that you use the PSE-SW8G series with our adaptor products as detailed below: MS-180-56 MS-270-56 Maximum output 56VDC/3.21A 56VDC/4.82A PSE-SW8G44A4 PSE-SW8G44A4 Related model PSE-SW8G44B4 PSE-SW8G44B4 PSE-SW8G44D4 PSE-SW8G44D4 MSTRONIC CO., LTD.
Page 7
If a port LED is off, go back and check for connectivity problems between that port and the network device connected. The maximum cable length for 10/100/1000BaseT with Cat 5 twisted pair cables is typically 100m (328 ft.). MSTRONIC CO., LTD.
Page 8
The yellow PoE LED will light up when the cable is correctly connected. Refer to the LED Indicator section for descriptions of each LED indicator. If a port LED is off, go back and check for connectivity problems between that port and the network device connected. MSTRONIC CO., LTD.
Page 9
IEEE 802.3af/at standard in the network. The PoE Switch can be installed in a more appropriate position for better performance to extend Ethernet to 200 meters. The following figure is an example of a network application for the PoE Switch. MSTRONIC CO., LTD.
We recommend that you use the PSE-SW8G series with our adaptor products as detailed below: MS-180-56 MS-270-56 Maximum output 56VDC/3.21A 56VDC/4.82A PSE-SW8G44A4 PSE-SW8G44A4 Related model PSE-SW8G44B4 PSE-SW8G44B4 PSE-SW8G44D4 PSE-SW8G44D4 Noted: When use MS-180-56, need to parallel 2 PS for all 7 port full load output. MSTRONIC CO., LTD.
B (3,6) data pair C plus V+(4,5) data pair D plus V-(7,8) mode A+B:data pair A plus V+(1,2) data pair B plus V-(3,6) data pair C plus V+(4,5) data pair D plus V-(7,8) Port 8, 4 pairs PD MSTRONIC CO., LTD.
Page 12
DC power supply or Port 8 (UPLINK) from network switch or midspan IEEE802.3af 44V~57V IEEE802.3at 51V~57V Power consumption 5W without PD loading Power efficiency 83% at full load Operating temperature 0℃~ 70℃ Operation humidity 90% relative humidity, non-condensing Storage temperature -30℃~+85℃ Dimensions 40mm(H)x190mm(W)x119mm(D) MSTRONIC CO., LTD.
Need help?
Do you have a question about the PSE-SW8G44A4 and is the answer not in the manual?
Questions and answers