6.2.15 Check DC Connect (15 and 23 target duplicators only)

The Check DC Connect option allows you to configure whether or not the duplicator checks for any
other daisy chain connected duplicators during bootup.
Tap the 'ENT' button to change this option.
‫٭‬
• [
] – Check DC Connect is enabled. When the duplicator is powered on, it will check for other
daisy chain connected duplicators while it is booting up.
• [
] – Check DC Connect is disabled (default). When the duplicator is powered on, it will skip
checking for other daisy chain connected duplicators and proceed with booting up in standalone
mode.

6.2.16 Set Max DC Count (15 and 23 target duplicators only)

The more duplicators you have connected through daisy chain, the longer it will take to initialize
during bootup. The Set Max DC Count option allows you to configure the maximum number of
duplicators the system checks for during bootup. Each duplicator has a different value:
• 15 Target Duplicator value = 4
• 23 Target Duplicator value = 6
So for example, if you are connecting two 15 Target Duplicators then you would set this value to 8.
If you were connecting 2x 23 Target Duplicators then you would set this value to 12. If you were
connecting a 15 Target Duplicator to a 23 Target Duplicator then this value should be set to 10.
The Set Max DC Count can be set from 1 to 32.
Tap the 'ENT' button and then press the UP/DoWN buttons to change this option's setting.
Tap the 'ENT' button to set the Max DC Count.

6.2.17 Set DC Connect Time (15 and 23 target duplicators only)

The more duplicators you have connected through daisy chain, the longer it will take to initialize
during bootup. The Set DC Connect Time option allows you to configure the maximum amount of
time that the system checks for daisy chain connected duplicators during bootup.
The Set DC Connect Time can be set from 0 to 999. The default value is set to 999.
Tap the 'ENT' button and then press the UP/DoWN buttons to change this option's setting.
Tap the 'ENT' button to set the DC Connect Time.