PRODUCT DATA

MODEL
NUMBER
Cooling
52SQD207---3
7,100/ 6,900
52SQD307---3
7,100/ 6,900
52SQE209---3
9,000/ 8,800
52SQE309---3
9,000/ 8,800
52SQC212---3
12,000/11,800 10,700/10,600
52SQC312---3
12,000/11,800 10,700/10,600 11,600/ 9,500
52SQC512---3
12,000/11,800 10,700/10,600 16,900/13,600
52SQC214---3
13,500/13,200 11,000/11,000
52SQC314---3
13,500/13,200 11,000/11,000 11,600/ 9,500
52SQC514---3
13,500/13,200 11,000/11,000 16,900/13,600
POWER
MODEL
FACTOR
NUMBER
Horsepower
(%)
52SQD207---3
97
52SQD307---3
52SQE209---3
95
52SQE309---3
52SQC212---3
52SQC312---3
98
52SQC512---3
52SQC214---3
52SQC314---3
98
52SQC514---3
LEGEND
EER — Energy Efficiency Ratio
*Rated in accordance with ARI Standard 310/380-93.
Coefficient of Performance (COP) at 47 F outdoor ambient temperature.
**Electric resistance heater power and fan motor power.
PERFORMANCE AND ELECTRICAL DATA
MODEL 52SQ (230/208 V)
CAPACITY* (Btuh)
Heating
Rev. Cyc.
Electric
6,100/ 6,000
7,800/ 6,400
6,100/ 6,000 11,600/ 9,500
8,000/ 7,800
7,800/ 6,400
8,000/ 7,800 11,600/ 9,500
7,800/ 6,400
7,800/ 6,400
FAN MOTOR
Full Load
Indoor CFM
Amps
HI/LO
1
/
0.6
280/200
15
/
0.78
350/300
1
8
1
/
1.0
380/310
6
1
/
0.78
350/300
8
UNIT NAMEPLATE VOLTAGE
OUTLET RATED VOLTS/AMPS
OUTLET BLADE CONFIGURATION
FEMALE RECEPTACLE MANUFACTURER'S
PART NO.
Hubbell
P&S
GE
Arrow-Hart
NEMA CONFIGURATION
TIME DELAY FUSE OR HACR
CIRCUIT BREAKER (AMPS)
HEATER (KILOWATTS)
HACR — Heating, Air Conditioning, and Refrigeration
NEMA — National Electrical Manufacturers Association
*May be used for 15-amp applications if fused for 15 amps.
VOLTAGE
HEATER
EER
COP†
RANGE
kW
(Volts)
2.3
10.5/10.5 3.1/3.1
253-198
3.4
10.5/10.5 3.1/3.1
2.3
9.3/ 9.3 2.8/2.8
253-187
3.4
9.3/ 9.3 2.8/2.8
2.3
9.0/ 9.0 2.8/2.8
3.4
9.0/ 9.0 2.8/2.8
253-198
5.0
9.0/ 9.0 2.8/2.8
2.3
8.8/ 8.8 2.6/2.6
3.4
8.8/ 8.8 2.6/2.6
253-187
5.0
8.8/ 8.8 2.6/2.6
MAX FUSE
MIN.
RECEP-
SIZE
CIRCUIT
(Amp)
(Amp)
15
13.1
20
19.1
15
13.4
20
19.4
15
12.3
20
18.0
30
24.9
15
13.4
20
19.4
30
28.0
RECEPTACLES AND FUSE TYPES
LEGEND
27
AMPS
Cooling
Heating**
Cooling
2.9/3.1
10.6/ 9.6
675/ 655 2440/2040
2.9/3.1
15.4/14.2
675/ 655 3540/2990
4.4/4.6
10.9/ 9.8
968/ 946 2510/2070
4.4/4.6
15.7/14.4
968/ 946 3610/3020
5.8/6.2
11.0/ 9.9 1333/1311 2500/2075
5.8/6.2
15.8/14.5 1333/1311 3600/3025
5.8/6.2
22.7/20.0 1333/1311 5200/4175
6.9/7.4
10.9/ 9.8 1530/1500 2510/2070
6.9/7.4
15.7/14.4 1530/1500 3610/3020
6.9/7.4
22.6/19.9 1530/1500 5210/4170
R-22
DEHUMIDIFI-
TACLE
CHARGE
CATION
TYPE
(oz)
(Pints/Hr)
A
24
1.3
B
A
26
2.3
B
A
B
34
3.3
C
A
B
37
4.3
C
230/208
250/15
250/20
A
5661
5461
5661
5871
GE4069-1
GE4182-1
5661
5861
6-15R
6-20R
15
20*
2.3
3.4
WATTS
Heating
APPROX.
SHIP WT.
(lb)
125
128
129
130
250/30
B
C
9330
5930
GE4139-3
5700
6-30R
30
5.0

Hide quick links: