Carrier 40MVC Product Data

Carrier 40MVC Product Data

High-wall duct free split system
Hide thumbs Also See for 40MVC:

Advertisement

40MVC / 38MVC
40MVQ / 38MVQ
High---Wall Duct Free Split System
Sizes 009 to 024
The ideal compliment to your ducted system when it is impractical
or prohibitively expensive to use ductwork.

Product Data

INDUSTRY LEADING

FEATURES / BENEFITS

AN INEXPENSIVE AND CREATIVE
SOLUTION TO DESIGN PROBLEMS.
The 38/40MVC(Q) series duct- -free split systems are a matched
combination of an outdoor condensing unit and an indoor fan coil
unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling.
selection of fan coils permits inexpensive and creative solutions to
design problems such as:
the environmentally sound refrigerant
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors.
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.
S
Add- -ons to current space (an office or family room
addition)
S
Special space requirements
S
When changes in the load cannot be handled by the
existing system.
S
When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
S
Historical renovations or any
preserving the look of the original structure is essential.
This
application where
Advanced system

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 40MVC

  • Page 1: Product Data

    FEATURES / BENEFITS AN INEXPENSIVE AND CREATIVE SOLUTION TO DESIGN PROBLEMS. The 38/40MVC(Q) series duct- -free split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
  • Page 2 This makes the 38/40MVC,MVQ duct- -free split systems the equipment of choice, EASY- -TO- - USE CONTROLS especially in retrofit situations.
  • Page 3: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE INDOOR UNIT 3--- 01 Voltage --- --- 30VDC 1 --- 115 ---1 ---60 Fan Coil Unit 3 --- 208/230 ---1 ---60 Nominal Capacity 009 --- 3/4 Ton 012 --- 1 Ton Unit Type 018 --- 1 ---1/2 Ton MVC --- Cooling Only 024 --- 2 Tons MVQ --- Heat Pump...
  • Page 4: Standard Features And Accessories

    STANDARD FEATURES AND ACCESSORIES INDOOR UNITS Ease Of Installation Mounting Brackets Low Voltage Controls Comfort Features Microprocessor Controls Wireless Remote Control Automatic Air Sweep Air Direction Control Auto Restart Function Cold Blow Protection On Heat Pumps Turbo Mode On Sizes 9K and 12 K Auto Changeover On Heat Pumps Energy Saving Features Sleep Mode...
  • Page 5: Service Valve Locations

    DIMENSIONS - - INDOOR A07336 Model Size Operating Weight lb (kg) in. (mm) in. (mm) in. (mm) 32.09 (815) 11.02 (280) 7.68 (195) 17.6 (8) 35.67 (906) 11.26 (286) 9.25 (235) 25.3 (11.5) 49.21 (1250) 12.80 (325) 9.06 (230) 39.6 (18) 49.21 (1250) 12.80 (325) 9.06 (230)
  • Page 6 CLEARANCES - - INDOOR 6" (0.15m) min. 5" 5" (0.13m) (0.13m) min. min. (1.8m) A07891 Fig. 2 – Indoor unit clearance CLEARANCES - - OUTDOOR Air-inlet Air-outlet A07894 UNIT 9k and 12k in. (mm) 18k and 24k in. (mm) 24 (610) 24 (610) 24 (610) 36 (914)
  • Page 7: Physical Data

    PHYSICAL DATA Outdoor Unit 38MVC System Voltage 115 V 115 V 208/230 208/230 208/230 Nominal Capacity (Btuh) 9000 12000 12000 18000 24000 Operating Weight lb(kg) 70.4(32) 79.2(36) 79.2(36) 116.6(53) 149.6(68) Refrigerant Type R---410A Metering Device Capillary Tube at Outdoor Charge lb (kg) 2.3 (1.0) 2.9 (1.3) 3.0 (1.4)
  • Page 8 PHYSICAL DATA (CONT.) Indoor Unit 40MVC System Voltage 115 or 208/230 208/230 208/230 Nominal Capacity (Btuh) 9000 12000 18000 24,000 Operating Weight lb(kg) 17.6(8) 25.3(11.5) 39.6(18) 39.6(18) Refrigerant Type R---410A Metering Device Capillary Tube at Outdoor Charge (lb) 2.3(1.0) 2.9(1.3) 4.4(2.0)
  • Page 9 PHYSICAL DATA (CONT.) Indoor Unit 40MVQ System Voltage 115 or 208/230 208/230 208/230 Nominal Capacity (Btuh) 9000 12000 18000 24000 Operating Weight lb (kg) 17.6 (8) 25.3 (11.5) 39.6 (18) 39.6 (18) Refrigerant Type R---410A Metering Device Capillary Tube at Outdoor Charge lb (kg) 2.35 (1.1) 3.0 (1.4)
  • Page 10: Performance Data

    PERFORMANCE DATA COOLING CAPACITIES 38MVC(Q)009- -1 / 40MVC(Q)009- -1 Air Entering Evaporator --- Cfm/BF Temp _F (_C) 190/0.04 259/0.04 327/0.05 Air Entering Air Entering Evaporator --- Ewb _F (_C) Condenser (Edb) (13.89) (16.67) (19.44) (22.22) (13.89) (16.67) (19.44) (22.22) (13.89) (16.67)
  • Page 11 PERFORMANCE DATA (CONT.) COOLING CAPACITIES 38MVC(Q)012- -1 / 40MVC(Q)012- -1 Air Entering Evaporator --- Cfm/BF Temp _F (_C) 339/0.04 367/0.04 427/0.05 Air Entering Air Entering Evaporator --- Ewb _F (_C) Condenser (Edb) 57 (13.89) (16.67) (19.44) (22.22) (13.89) (16.67) (19.44) (22.22)
  • Page 12 PERFORMANCE DATA (CONT.) COOLING CAPACITIES 38MVC(Q)012- -3 / 40MVC(Q)012- -3 Air Entering Evaporator --- Cfm/BF Temp _F (_C) 339/0.04 367/0.04 427/0.05 Air Entering Air Entering Evaporator --- Ewb _F (_C) Condenser (Edb) (13.89) (16.67) (19.44) (22.22) (13.89) (16.67) (19.44) (22.22) (13.89)
  • Page 13 PERFORMANCE DATA (CONT.) COOLING CAPACITIES 38MVC(Q)018- -3 / 40MVC(Q)018- -3 Air Entering Evaporator --- Cfm/BF Temp _F (_C) 502/0.04 568/0.04 631/0.05 Air Entering Air Entering Evaporator --- Ewb (_F) Condenser (Edb) (13.89) (16.67) (19.44) (22.22) (13.89) (16.67) (19.44) (22.22) (13.89) (16.67)
  • Page 14 PERFORMANCE DATA (CONT.) COOLING CAPACITIES 38MVC(Q)024- -3 / 40MVC(Q)024- -3 Air Entering Evaporator --- Cfm/BF Temp _F (_C) 584/0.04 657/0.04 759/0.05 Air Entering Condenser Air Entering Evaporator --- Ewb (_F) (Edb) 21.41 23.09 24.52 25.73 22.21 23.60 24.95 26.13 23.21 24.19...
  • Page 20: Application Data

    If unit is exposed to strong winds it is drainage cannot be provided, unit should be equipped with recommended that a wind baffle be used. Contact your Carrier accessory condensate pump. High wall fan coil unit condensate representative for drawings.
  • Page 21: Refrigerant Lines

    36- -in (914 mm) should be buried. Provide a minimum 6- -in (152 mm) The 40MVC/MVQ unit is equipped with a microprocessor controls vertical rise to the service valves to prevent refrigerant to operate the system and give optimum levels of comfort and migration.
  • Page 22: Outdoor Units

    AIR THROW DATA APPROXIMATE AIR THROW ft. (m) UNIT CAPACITY Medium High 009 115v 14 (4.3 m) 18 (5.5) 28 (8.5) 012 115v 16 (4.9) 20 (6.1) 30 (9.1) 012 208/230v 16 (4.9) 20 (6.1) 30 (9.1) 018 208/230v 22 (6.7) 37 (8.2) 35 (10.7) 024 208/230v...
  • Page 33: Guide Specifications

    I. Operating Characteristics: Coil shall be copper tube with aluminum fins and galvanized steel The 40MVC, MVQ system shall have a minimum listed SEER tube sheets. Fins shall be bonded to the tubes by mechanical (seasonal energy efficiency ratio) of 13 at ARI conditions, and a expansion.
  • Page 34 GUIDE SPECIFICATIONS HORIZONTAL DISCHARGE OUTDOOR UNITS Size Range: 3/4 to 2 Ton Nominal Cooling Capacity / 3/4 to 2 Ton Nominal Heating Capacity Carrier Model Number: 38MVC/38MVQ PART 1 - - GENERAL D. Compressor: 1. Compressor shall be fully hermetic rotary type.

Table of Contents