40MB*F / 38MAQ
Floor Console Ductless Split System
Sizes 09 to 12

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
A PERFECT BALANCE BETWEEN
BUDGET LIMITS, ENERGY SAVINGS AND
COMFORT.
The 38/40MBF series ductless split systems are a matched
combination of an outdoor condensing unit and an indoor fan coil
unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the floor, against the wall. This
selection of fan coils permits creative solutions to design problems
such as:
S
S
S
S
S
The ideal compliment to your ducted system when it is
impractical or prohibitively expensive to use ductwork.
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors. Advanced system
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.
Add- -ons to current space (an office or family room
addition)
Special space requirements
When changes in the load cannot be handled by the
existing system.
When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
Historical renovations or any application where
preserving the look of the original structure is essential.

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 38MAQB09 Series

  • Page 1: Product Data

    40MB*F / 38MAQ Floor Console Ductless Split System Sizes 09 to 12 Product Data INDUSTRY LEADING FEATURES / BENEFITS A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT. The 38/40MBF series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
  • Page 2 LOW SOUND LEVELS BUILT- - IN RELIABILITY When noise is a concern, the ductless split systems are the answer. Ductless split system indoor and outdoor units are designed to The indoor units are whisper quiet. There are no compressors provide years of trouble- -free operation. indoors, either in the conditioned space or directly over it, and The floor console indoor units include protection against freeze- -up there is none of the noise usually generated by air being forced...
  • Page 3: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE INDOOR UNIT --- --- 40= FAN COIL UNIT VOLTAGE 3 = 208/230 ---1 ---60 MB = MODEL SYSTEM TYPE Q = HEAT PUMP B=ALL SIZES NOT USED NOMINAL CAPACITY INDOOR FAN COIL TYPE 09 --- 3/4 TON 12 --- 1 TON F= FLOOR CONSOLE OUTDOOR UNIT...
  • Page 4: Standard Features And Accessories

    STANDARD FEATURES AND ACCESSORIES INDOOR UNITS Ease Of Installation Mounting Brackets Low Voltage Controls Comfort Features Microprocessor Controls Wired Remote Control Wireless Remote Control Automatic Horizontal Air Sweep Air Direction Control Auto Restart Function Cold Blow Protection On Heat Pumps Freeze Protection Mode On Heat Pumps Turbo Mode Silence Mode...
  • Page 5 DIMENSIONS - - INDOOR Fig. 2 – Indoor Unit UNIT SIZE Height in (mm) 8.27 (210) 8.27 (210) Width in (mm) 27.56 (700) 27.56 (700) Depth in (mm) 23.62 (600) 23.62 (600) Weight--- Net Lb (kg.) 32.41 (14.7) 32.41 (14.7) DIMENSIONS - - OUTDOOR Fig.
  • Page 6 CLEARANCES - - INDOOR Fig. 4 – Indoor Unit Clearance CLEARANCES - - OUTDOOR Air-inlet Air-outlet Fig. 5 – Clearances Outdoor Minimum Value UNIT in. (mm) 24 (609) 24 (609) 24 (609) 4 (101) 4 (101)
  • Page 7: Specifications

    SPECIFICATIONS SIZE Outdoor Model 38MAQB09--- --- --- 3 38MAQB12--- --- --- 3 SYSTEM Indoor Model 40MBQB09F--- --- 3 40MBQB12F--- --- 3 Energy Star Cooling Rated Capacity Btu/h 9,000 12,000 Cooling Cap. Range Min --- Max Btu/h 3,500~ 11,000 4,000~ 13,000 SEER 20.0 20.5...
  • Page 8: Cooling Performance Data

    COOLING PERFORMANCE DATA COOLING OUTDOOR CONDITIONS (DB) Model Indoor Indoor 77F(25C) 86F(30C) 95F(35C) 104F(40C) 113F(45C) 122F(50C) Conditions DB Conditions WB 7.41 7.82 9.73 8.34 6.12 69.8F(21C) 59F(15C) 6.64 6.69 8.18 7.37 4.36 3.74 Input 0.35 0.54 0.81 0.75 0.75 7.76 9.16 9.89 8.62...
  • Page 9: Application Data

    APPLICATION DATA UNIT SELECTION SYSTEM OPERATING CONDITIONS Select equipment to either match or is slightly less than the OPERATING RANGE anticipated peak load. This provides better humidity control, fewer Min / Max ° F (° C) unit cycles, and less part- -load operation. Cooling Heating For units used in spaces with high sensible loads, base equipment...
  • Page 10: Control System

    CAUTION WIRING All wires must be sized per NEC (National Electrical Code) or EQUIPMENT DAMAGE HAZARD CEC (Canadian Electrical Code) and local codes. Use the Electrical Failure to follow this caution may result in equipment Data table MCA (minimum circuit amps) and MOCP (maximum damage or improper operation.
  • Page 11: Air Flow Data

    AIR FLOW DATA SYSTEM SIZE High Indoor (CFM) Medium Outdoor (CFM) SOUND PRESSURE SYSTEM SIZE Cooling operation Indoor Sound dBa (L/M/H) 37/38/41 34/41/45 Pressure Heating operation Indoor Sound dBa (L/M/H) 37/38/41 34/41/45 Pressure Outdoor sound pressure level 55.5 SOUND POWER SYSTEM SIZE Cooling operation Indoor Sound dBa (L/M/H)
  • Page 12: Fan And Motor Specifications

    FAN AND MOTOR SPECIFICATIONS SYSTEM SIZE (208--- 230V) (208--- 230V) material Type LX--- 370*80*8--- 7JN LX--- 370*80*8--- 7JN Indoor fan Diameter inch 14.6 14.6 Height inch 3.15 3.15 Model RD--- 280--- 20--- 8A RD--- 280--- 20--- 8A Type Phase 0.21 0.21 Insulation class Safe class...
  • Page 13: Wiring Diagram

    WIRING DIAGRAM Fig. 7 – Wiring Diagram - - Sizes 9 and 12 INDOOR UNIT CONTROL BOARD INDOOR UNIT CODE PART NAME Input: 230VAC High voltage Connection of the terminal ‘Input: 230VAC High voltage Connection of the terminal Output: 24VDC Between CN2 Connection of the S signal Output: 12VDC Connection of the Lower outlet swing motor Output: 5VDC Connection of the Room and Pipe temperature CN10...
  • Page 14: Guide Specifications

    GUIDE SPECIFICATIONS INDOOR WALL- - MOUNTED FLOOR CONSOLE DUCTLESS UNITS Size Range: 3/4 to 1 Ton Nominal Cooling and Heating Capacity Carrier Model Number: 40MB*F PART 1 - - GENERAL The unit shall have the following functions as a minimum: 1.
  • Page 15 GUIDE SPECIFICATIONS HORIZONTAL DISCHARGE DUCTLESS OUTDOOR UNITS Size Range: 3/4 to 1 Ton Nominal Cooling and Heating Capacity Carrier Model Number: 38MAQ PART 1 - - GENERAL 2. Compressor shall be equipped with oil system, operating oil charge, and motor. Internal overloads shall protect the 1.01 System Description...
  • Page 16 Copyright 2015 Carrier Corp D 7310 W. Morris St. D Indianapolis, IN 46231 Edition Date: 11/15 Catalog No: 38--- 40MBF--- 03PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: 38--- 40MBF--- 02PD...