Carrier 52S Architects And Engineers' Manual page 28

Packaged terminal air conditioners and heat pumps
Table of Contents

Advertisement

PRODUCT DATA (cont)
CAPACITY* (Btuh)
MODEL
NUMBER
Cooling
52SQD207---4
7,100
52SQD307---4
7,100
52SQE209---4
9,000
52SQE309---4
9,000
52SQC212---4
12,000
52SQC312---4
12,000
52SQC512---4
12,000
52SQC214---4
13,500
52SQC314---4
13,500
52SQC514---4
13,500
POWER
MODEL
FACTOR
NUMBER
%
52SQD207---4
97
52SQD307---4
52SQE209---4
98
52SQE309---4
52SQC212---4
52SQC312---4
98
52SQC512---4
52SQC214---4
52SQC314---4
98
52SQC514---4
EGEND
L
EER — Energy Efficiency Ratio
*Rated in accordance with ARI Standard 310/380-93.
†Coefficient of Performance (COP) at 47 F outdoor ambient temperature.
**Electric resistance heater power and fan motor power.
††All 265-v units require either the Accessory Hard-Wire Kit or the Accessory Cord-
Connected Kit for installation. Use of the Accessory Cord-Connected Kit requires
the installation of the Subbase along with a field-supplied receptacle. Receptacle
configurations of the Accessory Cord-Connected Kit are shown at right.
PERFORMANCE AND ELECTRICAL DATA
MODEL 52SQ (265 V)
HEATER
Heating
kW
Rev. Cycle Electric
6,000
7,800
2.3
6,000
11,600
3.4
8,000
7,800
2.3
8,000
11,600
3.4
11,000
7,800
2.3
11,000
11,600
3.4
11,000
17,000
5.0
11,000
7,800
2.3
11,000
11,600
3.4
11,000
17,000
5.0
FAN MOTOR
Full
Indoor
Horsepower
Load
CFM
Amps
HI/LO
/
0.56
280/200
1
15
1
/
0.7
350/300
8
/
0.8
380/310
1
6
1
/
0.7
350/300
8
UNIT NAMEPLATE VOLTAGE
OUTLET RATED VOLTS/AMPS
OUTLET BLADE CONFIGURATION
FEMALE RECEPTACLE MANUFACTURER'S
PART NO.
Arrow-Hart
Hubbell
Eagle
NEMA CONFIGURATION
TIME DELAY FUSE OR HACR
CIRCUIT BREAKER (AMPS)
HEATER (KILOWATTS)
HACR — Heating, Air Conditioning, and Refrigeration
NEMA — National Electrical Manufacturers Association
VOLT
EER
COP†
RANGE
10.5
2.9
10.5
2.9
9.3
2.8
9.3
2.8
9.0
2.8
292-239
9.0
2.8
9.0
2.8
8.8
2.7
8.8
2.7
8.8
2.7
MAX. FUSE
MIN.
SIZE
CIRCUIT
(Amps)
AMPS
15
11.6
20
16.8
15
11.6
20
16.8
15
11.8
20
16.9
25
24.5
15
11.7
20
16.8
25
24.5
RECEPTACLES AND FUSE TYPES
LEGEND
28
AMPS
Cooling
Heating**
Cooling
2.9
9.3
2.9
13.4
3.8
9.4
3.8
13.5
5.2
9.5
1333
5.2
13.6
1333
5.2
19.7
1333
5.9
9.5
1535
5.9
13.6
1535
5.9
19.7
1535
RECEP-
R-22
DEHUMIDI-
TACLE
CHARGE
FICATION
TYPE††
(oz)
(Pints/Hr)
A
26
3.00
B
A
26
2.33
B
A
B
34
3.40
C
A
B
37
4.20
C
265
277/15
277/20
A
5302
7621
834B-BOX
384B-BOX
7-15R
7-20R
15
20
2.3
3.4
WATTS
Heating
675
2435
675
3535
968
2435
968
3535
2508
3608
5208
2505
3605
5205
APPROX.
CHASSIS
SHIP WT
(lb)
125
128
129
130
277/30
B
C
5795N
9315
7-30R
30
5.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents